    1. Overview & Purpose

    ️· Product: SVA Signal Converter
    ️· Function: A signal converter designed to receive a process signal (typically from a sensor) and convert it into a standard output signal (current or voltage).
    ️· Application: Used in industrial automation, process control, and similar applications.

    2. Key Specifications

    ️· Accuracy: ±0.2% of span (very good accuracy)
    ️· Temperature Coefficient: ±0.02%/°C (stability with temperature changes)
    ️· Response Time: ≤ 0.5 seconds (fast response to changes in the input signal)
    ️· Input Signal: Accepts current or voltage signals from sensors (specific range dependent on the chosen configuration - this isn't directly stated but implied).
    ️· Output Signal: Can be configured as either current or voltage output.
    - Current Output: 0-20mA or 4-20mA (standard industrial ranges)
    - Voltage Output: 0-5V or 0-10V (common voltage ranges)
    ️· Power Consumption:
    - AC: Approx. 10 VA, 5 W max.
    - DC: ≤ 5 W
    ️· Operating Temperature: -5 to +50°C (23 to 122°F)
    ️· Operating Humidity: 30 to 90 %RH (non-condensing)
    ️· Weight: 300g (0.66 lb)

    3. Electrical Safety & Isolation

    ️· Reinforced Insulation: Input to power: 300V (provides a high level of electrical isolation)
    ️· Basic Insulation: Input to Output: (Less robust than reinforced, but still provides isolation)
    ️· Dielectric Strength: 2000 V AC @ 1 minute (ability to withstand high voltage without breakdown)

    4. Regulatory Compliance

    ️· EU Conformity: Complies with EMC and Low Voltage Directives.
    ️· RoHS Directive: Complies with restrictions on hazardous substances.

    5. Design & Features

    ️· DIN Rail Mounting: Designed for easy installation on standard DIN rails.
    ️· Compact Size: Space-saving design.
    ️· Input Shunt Resistor: Indicates that the unit has an internal shunt resistor for current input signal conversion (important for current loop applications).
    ️· Modular Design (Implied): The schematic and connection diagram suggest a modular design with key functional blocks (Isolation, Amplifier, Output Driver)

    6. Important Considerations/Notes:

    ️· Configuration: The document does *not* specify how the converter is configured for input type, output type, or signal ranges. This is likely done via DIP switches, jumpers, or software. You will need the user manual to configure it properly.
    ️· Load Effect: The load effect specifications are important for ensuring the output signal is accurate under varying load conditions.
    ️· External Power Supply: An external power supply is required to operate the converter. The voltage is not specified, and you will need the user manual for more information.
    ️· Schematic & Connection Diagram: This diagram provides a high-level view of the internal components. Refer to the user manual for detailed wiring instructions.

    To effectively use the SVA signal converter, you *must* consult the full user manual. This document provides a good overview of the key features and specifications, but doesn's provide all the information needed for configuration and proper use.

    1. Overview & Purpose

    ️· Product: SVA Signal Converter
    ️· Function: A signal converter designed to receive a process signal (typically from a sensor) and convert it into a standard output signal (current or voltage).
    ️· Application: Used in industrial automation, process control, and similar applications.

    2. Key Specifications

    ️· Accuracy: ±0.2% of span (very good accuracy)
    ️· Temperature Coefficient: ±0.02%/°C (stability with temperature changes)
    ️· Response Time: ≤ 0.5 seconds (fast response to changes in the input signal)
    ️· Input Signal: Accepts current or voltage signals from sensors (specific range dependent on the chosen configuration - this isn't directly stated but implied).
    ️· Output Signal: Can be configured as either current or voltage output.
    - Current Output: 0-20mA or 4-20mA (standard industrial ranges)
    - Voltage Output: 0-5V or 0-10V (common voltage ranges)
    ️· Power Consumption:
    - AC: Approx. 10 VA, 5 W max.
    - DC: ≤ 5 W
    ️· Operating Temperature: -5 to +50°C (23 to 122°F)
    ️· Operating Humidity: 30 to 90 %RH (non-condensing)
    ️· Weight: 300g (0.66 lb)

    3. Electrical Safety & Isolation

    ️· Reinforced Insulation: Input to power: 300V (provides a high level of electrical isolation)
    ️· Basic Insulation: Input to Output: (Less robust than reinforced, but still provides isolation)
    ️· Dielectric Strength: 2000 V AC @ 1 minute (ability to withstand high voltage without breakdown)

    4. Regulatory Compliance

    ️· EU Conformity: Complies with EMC and Low Voltage Directives.
    ️· RoHS Directive: Complies with restrictions on hazardous substances.

    5. Design & Features

    ️· DIN Rail Mounting: Designed for easy installation on standard DIN rails.
    ️· Compact Size: Space-saving design.
    ️· Input Shunt Resistor: Indicates that the unit has an internal shunt resistor for current input signal conversion (important for current loop applications).
    ️· Modular Design (Implied): The schematic and connection diagram suggest a modular design with key functional blocks (Isolation, Amplifier, Output Driver)

    6. Important Considerations/Notes:

    ️· Configuration: The document does *not* specify how the converter is configured for input type, output type, or signal ranges. This is likely done via DIP switches, jumpers, or software. You will need the user manual to configure it properly.
    ️· Load Effect: The load effect specifications are important for ensuring the output signal is accurate under varying load conditions.
    ️· External Power Supply: An external power supply is required to operate the converter. The voltage is not specified, and you will need the user manual for more information.
    ️· Schematic & Connection Diagram: This diagram provides a high-level view of the internal components. Refer to the user manual for detailed wiring instructions.

    To effectively use the SVA signal converter, you *must* consult the full user manual. This document provides a good overview of the key features and specifications, but doesn's provide all the information needed for configuration and proper use.

    Part No.SVB-B4-L3
    ManufacturerMSYSTEM
    Size102 Kbytes
    Pages3 pages
    DescriptionPlug-in Signal Conditioners M-UNIT
    Does ALLDATASHEET help your business so far?  [ DONATE ] 

    About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com