1. General Information
️· Model: MTU DS275D6S
️· Type: Generator Set (Open Power Unit)
️· Rating: Standby
️· Manufacturer: MTU Onsite Energy (Rolls-Royce Power Systems Brand)
️· Website: [www.mtuonsiteenergy.com](http://www.mtuonsiteenergy.com)
2. Engine Specifications
️· Model: 6R 1600 G70S
️· Type: 4-Cycle, 6-Inline
️· Displacement: 10.5 L (641 cu in)
️· Rated RPM: 1800
️· Max Power: 312 kWm (418 bhp)
️· Governor: Electronic Isochronous, ±0.25% speed regulation
️· Fuel Consumption (Standby):
- 100% Load: 74 L/hr (19.7 gal/hr)
- 75% Load: 60 L/hr (15.9 gal/hr)
- 50% Load: 46 L/hr (12.2 gal/hr)
️· Fuel System:
- Max Fuel Lift: 5 m (16 ft)
- Recommended Fuel: Diesel #2
3. Generator Specifications
️· Type: Brushless, Rotating Field
️· Voltage/Hertz: Not explicitly stated, but assumes standard configuration.
️· Short Circuit Capability: 300% (with optional PMG)
️· Harmonic Distortion: ≤ 5% (Total Harmonic Distortion)
️· Control Panel: UL Recognized, CSA Certified, NFPA 110 compliant, Digital, with LCD Display and Event Recording.
4. Cooling System
️· Type: Integral, Set-Mounted, Engine Driven Fan
️· Coolant Capacity: 82 L (21.7 gal)
️· Ambient Capacity: 50°C (122°F)
️· Water Pump Capacity: 277 L/min (73.1 gpm)
️· Heat Rejection: Details provided in the "Cooling System" section above.
5. Air & Exhaust Requirements
️· Air Flow (Standby):
- Aspirating: 30 m³/min (1,059.4 SCFM)
- Rad Cooled Unit: 396 m³/min (13,985 SCFM)
️· Exhaust Gas Volume (Stack Temp): 72 m³/min (2,542.7 CFM)
️· Maximum Allowable Back Pressure: 15 kPa (60.2 in H2O)
6. Dimensions & Weight
️· Dimensions (OPU): 3,658 x 1,883 x 1,855 mm (144 x 74.13 x 73 in)
️· Weight (Dry/Less Tank): 3,078 kg (6,785 lb)
7. Emissions Data (at 100% Load)
️· NOx + NMHC: 4.71 g/hp-hr
️· CO: 0.61 g/hp-hr
️· PM: 0.06 g/hp-hr
8. Regulatory Compliance
️· NFPA 110 Compliant
️· UL Recognized
️· CSA Certified
️· CE Approved
9. Important Notes/Cautions
️· Deration factors for Altitude and Temperature should be verified with MTU Onsite Energy.
️· Specifications are subject to change without notice.
️· Consult the Factory/MTU Onsite Energy Distributor for configuration options.
1. General Information
️· Model: MTU DS275D6S
️· Type: Generator Set (Open Power Unit)
️· Rating: Standby
️· Manufacturer: MTU Onsite Energy (Rolls-Royce Power Systems Brand)
️· Website: [www.mtuonsiteenergy.com](http://www.mtuonsiteenergy.com)
2. Engine Specifications
️· Model: 6R 1600 G70S
️· Type: 4-Cycle, 6-Inline
️· Displacement: 10.5 L (641 cu in)
️· Rated RPM: 1800
️· Max Power: 312 kWm (418 bhp)
️· Governor: Electronic Isochronous, ±0.25% speed regulation
️· Fuel Consumption (Standby):
- 100% Load: 74 L/hr (19.7 gal/hr)
- 75% Load: 60 L/hr (15.9 gal/hr)
- 50% Load: 46 L/hr (12.2 gal/hr)
️· Fuel System:
- Max Fuel Lift: 5 m (16 ft)
- Recommended Fuel: Diesel #2
3. Generator Specifications
️· Type: Brushless, Rotating Field
️· Voltage/Hertz: Not explicitly stated, but assumes standard configuration.
️· Short Circuit Capability: 300% (with optional PMG)
️· Harmonic Distortion: ≤ 5% (Total Harmonic Distortion)
️· Control Panel: UL Recognized, CSA Certified, NFPA 110 compliant, Digital, with LCD Display and Event Recording.
4. Cooling System
️· Type: Integral, Set-Mounted, Engine Driven Fan
️· Coolant Capacity: 82 L (21.7 gal)
️· Ambient Capacity: 50°C (122°F)
️· Water Pump Capacity: 277 L/min (73.1 gpm)
️· Heat Rejection: Details provided in the "Cooling System" section above.
5. Air & Exhaust Requirements
️· Air Flow (Standby):
- Aspirating: 30 m³/min (1,059.4 SCFM)
- Rad Cooled Unit: 396 m³/min (13,985 SCFM)
️· Exhaust Gas Volume (Stack Temp): 72 m³/min (2,542.7 CFM)
️· Maximum Allowable Back Pressure: 15 kPa (60.2 in H2O)
6. Dimensions & Weight
️· Dimensions (OPU): 3,658 x 1,883 x 1,855 mm (144 x 74.13 x 73 in)
️· Weight (Dry/Less Tank): 3,078 kg (6,785 lb)
7. Emissions Data (at 100% Load)
️· NOx + NMHC: 4.71 g/hp-hr
️· CO: 0.61 g/hp-hr
️· PM: 0.06 g/hp-hr
8. Regulatory Compliance
️· NFPA 110 Compliant
️· UL Recognized
️· CSA Certified
️· CE Approved
9. Important Notes/Cautions
️· Deration factors for Altitude and Temperature should be verified with MTU Onsite Energy.
️· Specifications are subject to change without notice.
️· Consult the Factory/MTU Onsite Energy Distributor for configuration options.
| Part No. | DS275D6S |
| Manufacturer | MTU |
| Size | 299 Kbytes |
| Pages | 4 pages |
| Description | DIESEL GENERATOR SET |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |