| Electronic Components Datasheet Search |
|
TMS320F2802 Datasheet(PDF) 113 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMS320F2802 Datasheet(HTML) 113 Page - Texas Instruments |
|
113 / 147 page ![]() tw(WAKE-INT) td(WAKE-STBY) td(IDLE−XCOL) Wake−up Signal X1/X2 or X1 or XCLKIN XCLKOUT STANDBY Normal Execution STANDBY Flushing Pipeline (A) (B) (C) (D) (E) (F) Device Status TMS320F2809, TMS320F2808, TMS320F2806 TMS320F2802, TMS320F2801, TMS320C2802 TMS320C2801, TMS320F28016, TMS320F28015 www.ti.com SPRS230N – OCTOBER 2003 – REVISED MAY 2012 Table 6-18. STANDBY Mode Timing Requirements TEST CONDITIONS MIN NOM MAX UNIT Without input qualification 3tc(OSCCLK) Pulse duration, external tw(WAKE-INT) cycles wake-up signal With input qualification(1) (2 + QUALSTDBY) * tc(OSCCLK) (1) QUALSTDBY is a 6-bit field in the LPMCR0 register. Table 6-19. STANDBY Mode Switching Characteristics PARAMETER TEST CONDITIONS MIN TYP MAX UNIT Delay time, IDLE instruction td(IDLE-XCOL) 32tc(SCO) 45tc(SCO) cycles executed to XCLKOUT low Delay time, external wake signal to program execution resume(1) Without input qualifier 100tc(SCO) • Wake up from flash cycles – Flash module in active With input qualifier 100tc(SCO) + tw(WAKE-INT) state td(WAKE-STBY) Without input qualifier 1125tc(SCO) • Wake up from flash cycles – Flash module in sleep With input qualifier 1125tc(SCO) + tw(WAKE-INT) state Without input qualifier 100tc(SCO) cycles • Wake up from SARAM With input qualifier 100tc(SCO) + tw(WAKE-INT) (1) This is the time taken to begin execution of the instruction that immediately follows the IDLE instruction. execution of an ISR (triggered by the wake up signal) involves additional latency. A. IDLE instruction is executed to put the device into STANDBY mode. B. The PLL block responds to the STANDBY signal. SYSCLKOUT is held for approximately 32 cycles (if CLKINDIV = 0) or 64 cycles (if CLKINDIV = 1) before being turned off. This delay enables the CPU pipe and any other pending operations to flush properly. C. Clock to the peripherals are turned off. However, the PLL and watchdog are not shut down. The device is now in STANDBY mode. D. The external wake-up signal is driven active. E. After a latency period, the STANDBY mode is exited. F. Normal execution resumes. The device will respond to the interrupt (if enabled). Figure 6-15. STANDBY Entry and Exit Timing Diagram Copyright © 2003–2012, Texas Instruments Incorporated Electrical Specifications 113 Submit Documentation Feedback Product Folder Link(s): TMS320F2809 TMS320F2808 TMS320F2806 TMS320F2802 TMS320F2801 TMS320C2802 TMS320C2801 TMS320F28016 TMS320F28015 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |