Electronic Components Datasheet Search
  British  ▼
ALLDATASHEET.CO.UK

X  

  • FRS-R-112

  • AI
    ## FRS-R-12: Technical Overview The **FRS-R-12** is a specific model of industrial-grade power fuse belonging to the **Fusetron™** series, manufactured by **Bussmann (Eaton)**. It is a Class RK5 current-limiting, dual-element, time-delay fuse. ### 1. Key Specifications The following table summarizes the primary electrical and physical characteristics of the FRS-R-12: | Feature | Specification | | :--- | :--- | | **Manufacturer** | Eaton (Bussmann Series) | | **Amperage Rating** | 12 Amps | | **Voltage Rating (AC)** | 600 Vac | | **Voltage Rating (DC)** | 300 Vdc | | **Interrupting Rating** | 200,000 Amps RMS Symmetrical (AC) | | **Class** | RK5 | | **Element Type** | Dual-Element (Time-Delay) | | **Body Material** | Fiberglass Tube | --- ### 2. Functional Design The FRS-R-12 is designed with a **dual-element** architecture, which allows it to handle different types of electrical faults differently: * **Thermal Element:** Handles low-level overloads. It provides a "time-delay," allowing temporary surges (like motor starting currents) to pass without blowing the fuse. It typically holds 500% of the rated current for a minimum of 10 seconds. * **Instantaneous Magnetic Element:** Handles high-level short circuits. If a massive spike in current is detected, the fuse reacts instantly to prevent equipment damage or fire. --- ### 3. Applications and Use Cases Because of its time-delay properties, this fuse is ideal for circuits with inductive loads. 1. **Motor Protection:** Provides excellent protection for motor branch circuits where high inrush currents are present. 2. **Transformer Protection:** Resists blowing during the "magnetizing inrush" that occurs when a transformer is energized. 3. **General Feeders:** Used in mains and branch circuit disconnects. --- ### 4. Comparison: RK5 vs. RK1 It is important to distinguish Class RK5 fuses from RK1 fuses, as they often share the same physical dimensions but have different performance levels. | Feature | Class RK5 (FRS-R) | Class RK1 (LPS-RK) | | :--- | :--- | :--- | | **Current Limiting** | Moderate | High | | **Best For** | General Purpose / Motors | Sensitive Electronics | | **Replacement** | Can be replaced by RK1 | Cannot be replaced by RK5 |
    ✨ Follow-up Questions
    • ⤷ What is the difference between FRS-R and FRN-R fuses?
    • ⤷ Can an FRS-R-12 fuse be used in a 240V circuit?
    • ⤷ How do I test if an FRS-R-12 fuse is blown using a multimeter?