Electronic Components Datasheet Search
  British  ▼
ALLDATASHEET.CO.UK

X  

  • KAC-AD3-R

  • AI
    ## Overview of the KAC-AD3-R The **KAC-AD3-R** is a specialized electronic device primarily used in industrial and security applications. It is an **Addressable Input Module** (often associated with KAC, a Honeywell brand) designed to interface conventional devices with an intelligent fire alarm control panel. --- ### Core Electronic Components The device consists of several key electronic subsystems that allow it to function within an addressable loop: | Component Type | Description | Function | | :--- | :--- | :--- | | **Microprocessor** | Low-power integrated circuit | Manages data communication and processes the device address. | | **Address Switches** | Rotary or DIP switches | Used to manually set the unique loop address (typically 01-99 or 01-159). | | **Status LED** | Surface-mount LED (Red) | Provides visual feedback (Blinking for polling, Steady for alarm). | | **Isolation Circuitry** | Built-in short circuit isolator | Protects the rest of the loop if a short occurs on the local branch. | | **I/O Terminals** | Screw-down terminal blocks | Physical connection points for the Loop (+/-) and the monitored device. | --- ### Key Technical Specifications The electronic performance of the KAC-AD3-R is defined by its power consumption and signaling capabilities: * **Operating Voltage:** Typically 15V to 32V DC (sourced from the signaling line circuit). * **Standby Current:** Extremely low (~300 $\mu$A) to allow hundreds of devices on a single loop. * **Communication Protocol:** Proprietary addressable protocol (e.g., OPAL or CLIP). * **End-of-Line (EOL) Resistor:** Requires a specific resistance value (often 47k$\Omega$) to monitor the integrity of the input wiring. --- ### Working Principle 1. **Polling:** The central control panel sends a digital signal down the wire. The **Microprocessor** in the AD3-R recognizes its unique address and sends back a "Status OK" pulse. 2. **Monitoring:** The module monitors the voltage across the input terminals. 3. **State Change:** If a connected switch (like a flow switch or non-addressable pull station) closes, the module detects the drop in resistance. 4. **Reporting:** During the next polling cycle, the module sends an "Active" or "Alarm" digital code to the panel. --- ### Wiring Interface Example ```text [ Loop In + ] ---- ( Terminal 1 ) [ Loop In - ] ---- ( Terminal 2 ) [ Input + ] ---- ( Terminal 3 ) --- [ EOL Resistor ] [ Input - ] ---- ( Terminal 4 ) --- [ EOL Resistor ] ```
    ✨ Follow-up Questions
    • ⤷ What is the specific EOL resistor value required for the KAC-AD3-R?
    • ⤷ How do you set the rotary address switches on this module?
    • ⤷ Can this module be used to control external relays
    • ⤷ or is it input-only?