M2AMS2-B1-R2/N
AI

The **M2AMS2-B1-R2/N** is a high-precision digital panel meter typically manufactured by **Autonics** (or similar industrial automation brands). It is designed to measure and display analog signals such as voltage or current in industrial environments.
---
## 1. Technical Specifications Overview
The electronic characteristics of this specific model are broken down in the table below:
| Feature | Specification Details |
| :--- | :--- |
| **Input Type** | DC Voltage / DC Current (Multi-input) |
| **Power Supply** | 100–240VAC 50/60Hz |
| **Display Method** | 4-digit 7-segment LED |
| **Output Type** | Relay Output (R2: 2-point relay) |
| **Transmission** | None (Standard Indicator/Controller) |
| **Measurement Accuracy** | ±0.1% F.S. ±1-digit |
| **Sampling Cycle** | 50ms |
---
## 2. Core Electronic Components & Functions
### A. Input Stage (Signal Conditioning)
The device features a high-impedance input stage that converts analog signals (e.g., 4-20mA, 0-10V) into a format the internal Microcontroller Unit (MCU) can process.
* **ADC (Analog-to-Digital Converter):** High-resolution converter ensuring a display range of -1999 to 9999.
* **Isolation:** The input circuitry is electronically isolated from the power supply to prevent ground loops and noise interference.
### B. Control & Logic (The "Brain")
* **Microprocessor:** Manages the scaling of the input signal, handles the high/low alarm logic, and drives the LED display.
* **EEPROM:** Non-volatile memory that stores user configurations (scaling values, alarm setpoints) even after power loss.
### C. Output Stage (Relay Logic)
The **"R2"** in the model code signifies the presence of two relay outputs.
* **Relay Type:** Typically SPST (Single Pole Single Throw) or SPDT.
* **Function:** Used for "Hi" and "Lo" alarm triggers. When the measured value crosses a set threshold, the internal electromagnet closes the contact to trigger external sirens, lights, or PLC inputs.
### D. Power Supply Unit (PSU)
* **Switching Mode Power Supply (SMPS):** Modern versions use an internal SMPS to handle a wide range of AC inputs (100-240V), providing stable DC voltage to the internal logic boards.
---
## 3. Terminal Connection Map
The back of the unit features a terminal block typically organized as follows:
1. **Power Terminals:** Connection for AC source.
2. **Input Terminals:** Terminals for the sensor or signal source (Polarity sensitive).
3. **Relay Output Terminals:** Terminals for AL1 (Alarm 1) and AL2 (Alarm 2) dry contacts.
---
## 4. Model Code Breakdown
| Segment | Meaning |
| :--- | :--- |
| **M2A** | Series Identifier (M2 Series Digital Meter) |
| **MS2** | Size / Standard (S2 frame) |
| **B1** | Power Supply (100-240VAC) |
| **R2** | **Relay Output 2 points** |
| **N** | No extra communication/transmission output |
- ⤷
How do I calibrate the scaling on the M2AMS2-B1-R2/N?
- ⤷ What is the maximum contact capacity of the R2 relay outputs?
- ⤷ Can this model be used to measure AC voltage instead of DC?