Electronic Components Datasheet Search
  British  ▼
ALLDATASHEET.CO.UK

X  

  • M5TS-24W-R

  • AI
    The **M5TS-24W-R** is a high-performance **Platinum Resistance Temperature Detector (RTD)** sensor manufactured by OMRON. This specific part is designed for industrial applications requiring high precision and stability in temperature measurement. --- ## 1. Technical Specifications The electrical and physical characteristics of the M5TS-24W-R are summarized in the table below: | Feature | Specification | | :--- | :--- | | **Element Type** | Pt100 (Platinum Resistance) | | **Wiring Configuration** | 3-wire system (compensates for lead resistance) | | **Temperature Range** | -50°C to +250°C (Typical) | | **Class/Accuracy** | Class A (High Precision) | | **Resistance at 0°C** | 100 $\Omega$ | | **Protective Tubing** | Stainless Steel (SUS316) | | **Lead Wire Type** | Vinyl-insulated or Fluororesin-insulated | --- ## 2. Key Electronic Components ### A. The Pt100 Element The "heart" of the device is a thin-film platinum resistor. Its electrical resistance increases linearly with temperature. * **Formula:** $R_t = R_0(1 + At + Bt^2)$ * This predictable linear behavior allows electronic controllers (PLCs/PID controllers) to convert resistance into an accurate temperature reading. ### B. 3-Wire Compensation Circuit The "W" in the part number often signifies the wiring method. The 3-wire setup is an electronic design choice to eliminate errors caused by the electrical resistance of the long lead wires: 1. **Wire 1 & 2:** Connected to one side of the sensor. 2. **Wire 3:** Connected to the other side. 3. **Operation:** The controller measures the resistance of the lead wires themselves and subtracts it from the total measured resistance to provide a "pure" sensor reading. ### C. Insulation and Shielding * **Dielectric Strength:** Designed to withstand high voltage (usually 500V AC for 1 minute) between the leads and the metal protective tube. * **Insulation Resistance:** Typically 100 M$\Omega$ or higher, ensuring that electrical noise does not interfere with the low-voltage signal. --- ## 3. Wiring Diagram Logic To integrate this part into an electronic circuit, the following wiring logic is used: ```text Controller Terminal M5TS-24W-R Leads [ A ] ------------------ (Red) [ B ] ------------------ (White) [ B'] ------------------ (White) ``` *The two white wires are internally connected at the sensor head to provide the compensation loop.* --- ## 4. Application Use Cases * **PID Control:** Used with OMRON E5_C series temperature controllers. * **Food Processing:** Due to the SUS316 stainless steel sheath which is resistant to corrosion. * **HVAC Systems:** For high-accuracy air or liquid flow temperature monitoring.
    ✨ Follow-up Questions
    • ⤷ What is the difference in accuracy between Class A and Class B for this RTD?
    • ⤷ How does a 3-wire RTD circuit compare to a 4-wire circuit in terms of noise rejection?
    • ⤷ Which OMRON temperature controllers are most compatible with the M5TS series?