Description A two chip solution, consisting of AT73C500 and AT73C501 (or AT73C502), offers all main features required for the measurement and calculation of various power and energy quantities in static Watt-hour meters. The devices operate according to IEC1036, class 1, specification. IEC 687, class 0.5 and 0.2 requirements are fulfilled when used with external temperature compensated voltage reference. Features • Fulfills IEC 1036, Class 1 Accuracy Requirements • Fulfills IEC 687, Class 0.5 and Class 0.2 Accuracy, with External Temperature Compensated Voltage Reference • Simultaneous Active, Reactive and Apparent Power and Energy Measurement • Power Factor, Frequency, Voltage and Current Measurement • Single and Poly Phase Operation • Three Basic Operating Modes: Stand-Alone Mode, Microprocessor Mode and Multi-Channel Mode • Flexible Interfacing, 8-bit Microprocessor Interface, 8-bit Status Output and Eight Impulse Outputs • Calibration of Gain and Phase Error • Compensation of the Non-Linearity of Low Power Measurement • Adjustable Starting Current and Meter Constant • Measurement Bandwidth of 1000 Hz • Tamper Proof Design • Single +5V Supply
|