15 / 22 page ![]() Rev 1, May-12-2016 Innovative PowerTM - 15 - www.active-semi.com Copyright © 2016 Active-Semi, Inc. ACT2803 APPLICATIONS INFORMATION In charge mode, the battery charger provides bias current to balance battery charge. The balance resistor is either connected to upper battery or lower battery depending on which battery voltage is higher. The balance resistor is connected in parallel with one battery that is higher than the other battery. For extremely unbalanced 2S batteries, the charger takes a few cycles to make two battery voltage balanced. For some applications, like removable dual cell batteries, a charger is required to balance dual cells in one charge cycle. In this case, the circuit shown in Figure 5 is recommended. The balance current through the 22 Ohm resistor needs to be higher than EOC current threshold. Figure 5: Cell balance LED Indication ACT2803 is designed 5 levels of PT pin voltage into 5 application patterns. A resistor is connected from PT pin to ground and the voltage at PT pin programs the LED indication patterns shown in Figure 6 . Figure 6: LED Indication In discharge mode, when battery voltage goes below LED1 threshold, LED1 starts flashing until Buck (discharge mode) turns off due to either light load or Buck UVLO. The flash frequencies for all the LEDs are 0.5Hz with 1s on and 1s off. In HZ mode, when PB is pressed for 40ms, Buck turns on. If VBAT<LED1, LED1 starts flashing until Buck turns off. Conventional indication patterns could behave to have two application. Setting RPT=4kΩ to have “Always On”, setting RPT=12kΩ to have “5s Indication”. The behaviors for both setting are same in charge mode. See below table for more information. Below shows 4 LED indication patterns. LED1-4 Refreshing Cycle Every time when VIN is plugged in or a PB is pushed, LED1, 2, 3, 4 turns on sequentially at 0.5s interval, like a LED scanning, and then goes into corresponding mode defined by PT pin. LED1-4 Fault Alarm Signal At fault conditions, actions are taken. In the meantime, all the 4 LEDs turn on/off with 0.5s on and 0.5s off for 10 seconds to send alarm signal out. The fault conditions include battery OVP, UVP, OTP. PCB Board Layout Guidance When laying out the printed circuit board, the following checklist should be used to ensure proper operation of the IC. 1. Arrange the power components to reduce the AC loop area. # INDICATION PATTERN RPT 1a Conventional Always On In Discharge 4kΩ 1b Conventional 5s Indication in Discharge 12kΩ 2 Breathing 5s Indication in Discharge 24kΩ 3 Bottom Charging 5s Indication in Discharge 40kΩ 4 Circulating 5s Indication in Discharge 56kΩ |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |