| Electronic Components Datasheet Search |
|
DR10E03XR Datasheet(PDF) 2 Page - Crydom Inc., |
|
|
|||||||||||||||||||||||||||||
DR10E03XR Datasheet(HTML) 2 Page - Crydom Inc., |
|
2 / 7 page ![]() Datasheet DIN Rail Mount INPUT SPECIFICATIONS (2) DRxxExx DRxxBxx DRxxDxx Description Control Voltage Range (6) 4-32 VDC 200-265 Vrms 18-36 Vrms (1) Minimum Turn-On Voltage 4.0 VDC 200 Vrms 18 Vrms Must Turn-Off Voltage 1.0 VDC 40 Vrms 4 Vrms Minimum Input Current for [mA] (7) 9 2.5 3.5 Maximum Input Current for [mA] (8) 11 3.3 8 1/2 Cycle 20 msec 20 msec Maximum Turn-on Time [msec] (8) (9) 1/2 Cycle 30 msec 30 msec Maximum Turn-off Time [msec] (10) 22/16 AWG 22/16 AWG 22/16 AWG GENERAL SPECIFICATIONS(2) Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms (11) Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -30 to 80 °C Ambient Storage Temperature Range -30 to 100 °C 4.4-7.0 in-lb (0.5-0.8Nm) Recommended Terminal Screw Torque Range 109 Ohm Min/Max stranded/solid wire DRxxAxx 90-140 Vrms 90 Vrms 10 Vrms 3 5 20 msec 30 msec 22/16 AWG GENERAL NOTES (2) All parameters at 25°C unless otherwise specified. (3) For AC output frequency is 47-63Hz (5) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (6) DC control includes reverse polarity protection. (7) Input circuitry incorporates active current limiter. (8) Turn-on time for DC control random turn-on versions is 0.1 msec. (9) Turn-on time for DC output 600µsec. (10) Turn-off time for DC output 300 µsec. (11) 2500 Vrms for DC output. LC A, Resistive or Slightly Inductive Load Ratings: 3A @40°C ambient for DR24x03, 3A @ 40°C ambient for DR48x03 LC B, Motor Loads Ratings: 0.18KW @ 240VAC for DR24x03 and 0.375KW @ 480VAC DR48x13 Standards of Compliance IEC 62314 Shock and Vibration (Applies to all part numbers) Vibration Resistence according to IEC 60068-2-6: 0.35mm and 0.75mm Amplitude over 10-55 Hz Shock Resistance according to IEC 60068-2-27: 15g/11ms EMC (Applies to all part numbers) IEC 61000-4-2: Electrostatic Discharge- Level 3 IEC 61000-4-4: Electrically Fast Transients- Level 3 IEC 61000-4-5: Electrical Surges- Level 3 ANSI / ISA 12.12.01-2013 Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classified) locations This equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a tool suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only WARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations WARNING-Explosion Hazard- Substitution of any component may impair suitability for class I, Division 2 (4) See Derating curves (1) E option is UL certified for AC control voltage, but it works also with 18-36 VDC input range. Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |