25 / 36 page ![]() CS7622 DS322PP1 25 Fixed Gain Default = 00h; Read/Write (address 14h) Bit Number 765432 10 Bit Name RESERVED fixed_gain2 fixed_gain1 fixed_gain0 RESERVED Default 000000 00 Bit Mnemonic Function 7:6, 2:0 - Reserved 5:3 fixed_gain2-0 Fixed Gain: This is used to turn off the DRX functionality and apply a fixed gain to the input before reaching the ADC. A setting of 000 is used for normal oper- ation this will yield the largest dynamic range by switching the front end gain rel- ative to the amplitude of the input signal. The settings 001, 010, 011, and 100 are for fixed gains of 1x, 2x, 4x, and 8x respectively. Figure 18 shows the trans- fer function of the output of the ADC for a given input with the various fixed gain settings. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|