4 / 8 page ![]() Output Protection Circuitry Protected against false pulse on power-up, short-circuit protected Output Response Time Opposed Mode: 1.3 ms ON; 900 µs OFF All Other Modes: 700 µs ON/OFF NOTE: 120 ms delay on power-up; outputs do not conduct during this time. Indicators One Yellow and one Green LED (see Figure 1) Construction Polarized Retro Models: Thermoplastic elastomer housing with glass lens All Other Standard Models: Thermoplastic elastomer housing with polycarbonate lens Chemical-Resistant Models: Housing encased in PFA jacket; cable encased in 3/16 in O.D. PFA tubing Output Ratings OFF-state leakage current: NPN: 200 µA PNP: 10 µA ON-state saturation voltage: NPN: 1.25 V at 50 mA PNP: 1.45 V at 50 mA Vibration and Mechanical Shock All models meet MIL-STD-202F, Method 201A (Vibration: 10 Hz to 60 Hz maximum, 0.06 inch (1.52 mm) double amplitude, 10G maximum acceleration) requirements. Also meets IEC 60947-5-2 (Shock: 30G 11 ms duration, half sine wave) requirements. Connections Standard Models: 2 m (6.5 ft) or 9 m (30 ft) attached PVC cable, or 150 mm (6 in) pigtail with M8 or M12 threaded connection, depending on the model ordered Chemical-Resistant Models: 2 m (6.5 ft) cable encased in 3/16 in O.D. PFA tubing Environmental Rating Standard Models: IEC IP67 Chemical-Resistant Models: IEC IP67 (NEMA6) and PW12 1200 psi washdown per NEMA ICS5, Annex F-2002 Conditions Operating Temperature: –20 °C to +55 °C (–4 °F to +131°F) Storage Temperature: –30 °C to +75 °C (–22 °F to +167 °F) 95% at +50 °C maximum relative humidity (non-condensing) Certifications (Chemical-resistant models are not UR/UL approved.) Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Dimensions 3.5 mm (0.14") 22 mm (0.86") 23.1 mm (0.91") 3.4 mm (0.13") 5.1 mm (0.20") 15.0 mm (0.59") 4.7 mm (0.19") Polarized Retro Models M3 mounting screws included 8.0 mm (0.31") 12.4 mm (0.49") Ø 3 mm (0.12") max. torque 0.9 Nm (8 in-lbf) Emitter (opposed mode models) Emitter (all other models) Figure 1. Standard Models WORLD-BEAM® Q12 Series Sensor 4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 119223 Rev. K |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |