| Electronic Components Datasheet Search |
|
R55FVG Datasheet(PDF) 8 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
R55FVG Datasheet(HTML) 8 Page - Banner Engineering Corp. |
|
8 / 12 page ![]() R55F Series Fiber-Optic Color Mark Sensors page 8 Banner Engineering Corp. • Minneapolis, U.S.A. www.bannerengineering.com • Tel: 763.544.3164 Remote Programming The gray wire of the R55F may be connected to a remote switch or to a process controller to: - Set sensitivity via either Static or Dynamic TEACH mode - Set output response via SETUP mode - Disable the push button functions A remote programming switch is connected between the gray wire and dc common (see Hookup diagrams on page 11). The switch may be either a normally-open contact, or an open-collector NPN transistor with its emitter connected to dc common. Remote programming is accomplished using a specified sequence of input pulses. The duration of each pulse is defined as: 0.04 seconds < T < 0.8 seconds (40 ms < T< 800 ms) Remote Static TEACH Mode 1) Present the Output ON condition to the fiber sensing end and pulse the Remote TEACH input once. 2) Wait at least 0.8 seconds, present the Output OFF condition, and pulse the Remote TEACH input once. If sensing contrast is adequate, the sensor flashes one segment of the signal strength light bar for 3 seconds to indicate relative contrast, and then enters RUN mode. If contrast is too low, the sensor flashes five segments of the signal strength light bar in unison to warn of unacceptably low contrast, and returns to re-teach the Output ON condition (Step 1). Remote Static Single-Point TEACH The single-point TEACH may also be performed using the remote wire. Present the target and single-click the remote wire. Wait for at least 0.8 second, then double-click the remote wire. If the TEACH is successful, the sensor will flash the middle two LEDs of the bar graph, and return to RUN mode. Remote Dynamic TEACH Mode 1) Hold the TEACH input low for > 2 seconds 2) Continue holding the TEACH input low while presenting light and dark sensing conditions. Open switch when finished teaching. If sensing contrast is adequate, the sensor flashes one segment of the signal strength light bar for 3 seconds to indicate relative contrast, and then enters RUN mode. If contrast is too low, the sensor flashes five segments of the signal strength light bar in unison to warn of unacceptably low contrast, and returns to RUN mode with its previously taught conditions. Switch Open Switch Closed to dc common 0.04 < T < 0.8 sec Figure 4. Input pulse timing Present Output ON Condition Present Output OFF Condition > 0.8 sec TT Figure 5. Static TEACH mode Present Output ON Condition Double-Click > 0.8 sec TT T T Figure 6. Static Single-Point TEACH mode > 2 sec TEACH Light and Dark Conditions Figure 7. Dynamic TEACH mode |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |