| Electronic Components Datasheet Search |
|
TRG21 Datasheet(PDF) 2 Page - CINCON ELECTRONICS Corporation |
|
|
|||||||||||||||||||||||||||||
TRG21 Datasheet(HTML) 2 Page - CINCON ELECTRONICS Corporation |
|
2 / 2 page ![]() V12 2 Specifications TRG21 Series De-rating Curve INPUT SPECIFICATIONS: Voltage …....………........…........................................... 90~264Vac Frequency ………………………………………….……………..... 47 to 63Hz Input Current ……………………………………….……………..... 0.3 to 0.5A Inrush Current …………….…Cold Start@25℃............. 40A max. @230Vac Leakage Current …………………………………………………… 0.1mA max. OUTPUT SPECIFICATIONS: Voltage Accuracy ..........................................…………............... ±2.0% max. Line Regulation (note3) ……………….…………...................…. ±1.0% max. Load Regulation (note4) ………………......……….…….........…...... see table Hold-up Time …………………………….…………..…… 8ms typ. @115Vac SAFETY AND EMISSION: Short Circuit Protection …………….………………………….…… Continuous CE Directive ……………………………….……… 2004/108/EC, 93/42/EEC Over Voltage Protection(TVS) …… 115%-140% of nominal output voltage Emissions … EN60601-1/EN61204-3/EN55022/CISPR Class B, EN55024 GENERAL SPECIFICATIONS: Safety Approvals …….................. UL60601-1, IEC60601-1, EN60601-1 3 rd Isolation ………………………………..………… Input to output = 5,656VDC IEC60950-1,EN60950-1 Efficiency ……………………………………………………………….. see table NOTE: Switching Frequency ………………………………….………….. 100KHz typ. 1. Voltage accuracy is set of 60% rated load. Operating Temperature ............................... -20 ~ 60℃(see derating curve) 2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Storage Temperature ……………………………...….......……........ -25~85℃ Ripple & Noise measuring @20MHz BW. Cooling ………………………………….………………… Natural Convection 3. Line regulation is measured from high line to low line with full load. Humidity .................................................... 93% RH max. Non condensing 4. Load regulation is measured from 60% to full load and from 60% to MTBF ……. MIL-STD-217F, GB, at 25℃/115VAC ..……… 400Khrs min. 20% load (60% +/- 40% load). Dimensions ……….. 3.000x1.780x0.870 inches (76.20x45.20x22.10mm) Weight …………………………………………………… 140g(0.31Pounds) Mechanical Specification Tolerance:Inches:X.XXX±0.02 Millimeters:X.XX±0.5 All Dimensions are in inches(mm) 18AWG / 1220mm DC Plug :Right Angle(ψ5.5/ψ2.1) L12mm DC Plug type: V+ ─●)─ V- 0.008[0.20] IEC320/C8 48.031[1220.00]±1.969[50.00] 3.000[76.20] Typical at 25˚C, nominal line and 75% load, unless otherwise Specified 0% 20% 40% 60% 80% 100% -20 -10 0 10 20 30 40 50 60 Ambient Temperature( oC) 20LFM(Natural Convection) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |