2 / 4 page ![]() MODEL: MALN MALN SPECIFICATIONS ES-8163 Rev.1 Page 2/4 https://www.m-system.co.jp/ CONNECTION EXAMPLES SPD1 SPD1 SPD2 ACC1 ACC2 Protected device Circuit breaker G Circuit breaker Building Service entrance switch gear Equipotencial bonding terminal Switchgear Apparent energy meter (WHM) POWER (e.g.) Three phase/3-wire 220V AC SPD1 Class I Surge Protector Class II Surge Protector ACCESSORY MAL-230x SPD2 MALN-230 SPD3 MAKF-240x SPD4 MAKN-220x SPD5 MAT2-2404xx ACC1 CNB2-5 ACC2 CNB-3 *1. The circuit breaker's rating current must be of 150 A, and the rated interrupting capacity selected must be the grater between 30 kA or the highest amount of current that could be available in the circuit. For monitoring the operation of the circuit breaker we recommend also using the alarm switch (AL). *2. The use of RCD with time-delay overcurrent protection is recommended upon to prevent unnecessary operation with surge current (Recommended sensitivity current rating: 30mA) *3. Install an MCCB for backup saving of class II surge protector. Refer to the data sheets of the class II surge protector for details. *4. If the service entrance switchgear and switchgear or protective device wiring distance is more than 10 m, install the class II surge protector on the power supply downstream. Class II surge protector is the combination of SPD3 and SPD4 or SPD5 SPD5 *3 *1,*2 (N) L2 L1 L3 INSTALLATION EXAMPLES: Three phase/3-wire (delta connection) TT Systems Lightning is a natural phenomenon and this unit could receive surges exceeding the discharge withstand current rating. Then, there is a possibility of burning out and result in short-circuits because of exceeding the processing capacity. Upon to save a backup, the circuit breaker must be installed on the power supply side of the surge protector. Molded-case circuit breaker (MCCB) or residual current circuit breaker with overcurrent protection (RCD) can be used. Generator or transformer *4 Class II Surge Protector *4 Class II Surge Protector Class I Surge Protector Circuit breaker Circuit breaker |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |