| Electronic Components Datasheet Search |
|
VOT8024AM Datasheet(PDF) 3 Page - Vishay Siliconix |
|
|
|||||||||||||||||||||||||||||
VOT8024AM Datasheet(HTML) 3 Page - Vishay Siliconix |
|
3 / 10 page ![]() VOT8024AM www.vishay.com Vishay Semiconductors Rev. 1.2, 26-Oct-2018 3 Document Number: 84909 For technical questions, contact: optocoupleranswers@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Notes • Minimum and maximum values were tested requirements. Typical values are characteristics of the device and are the result of engineering evaluations. Typical values are for information only and are not part of the testing requirements (1) Static dV/dt Note • As per IEC 60747-5-5, § 7.4.3.8.2, this optocoupler is suitable for “safe electrical insulation” only within the safety ratings. Compliance with the safety ratings shall be ensured by means of protective circuits ELECTRICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified) PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT INPUT Forward voltage IF = 20 mA VF -1.2 1.4 V Reverse current VR = 6 V IR -0.05 10 μA OUTPUT Off-state current VDRM = 800 V IDRM -- 0.5 μA On-state voltage IT = 100 mA peak VTM -- 3 V Holding current IH - 400 - μA Zero cross inhibit voltage IF = rated IFT VINH -5 20 V Critical rate of rise of off-state voltage dV/dt (1) 1000 - - V/μs Leakage in inhibit state IF = rated IFT, rated VDRM, off-state IDRM2 - - 500 μA COUPLER Trigger current VTM = 3 V IFT -- 5 mA SAFETY AND INSULATION RATINGS (Tamb = 25 °C, unless otherwise specified) PARAMETER TEST CONDITION SYMBOL VALUE UNIT Climatic classification According to IEC 68 part 1 55 / 115 / 21 Comparative tracking index Insulation group IIIa CTI 175 Maximum rated withstanding isolation voltage According to UL1577, t = 1 min VISO 3750 VRMS Maximum transient isolation voltage According to DIN EN 60747-5-5 VIOTM 6000 Vpeak Maximum repetitive peak isolation voltage According to DIN EN 60747-5-5 VIORM 565 Vpeak Isolation resistance VIO = 500 V, Tamb = 25 °C RIO 1012 Ω VIO = 500 V, Tamb = 100 °C RIO 1011 Ω Output safety power PSO 300 mW Input safety current ISI 50 mA Input safety temperature TS 150 °C Creepage distance > 5 mm Clearance distance > 5 mm Insulation thickness DTI > 0.4 mm |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |