| Electronic Components Datasheet Search |
|
R3-GGLMP/CE Datasheet(PDF) 5 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3-GGLMP/CE Datasheet(HTML) 5 Page - M-System Co.,Ltd. |
|
5 / 10 page ![]() MODEL: R3-GSLMP1 R3-GSLMP1 SPECIFICATIONS ES-8275 Rev.2 Page 5/10 https://www.m-system.co.jp/ · Device: Commands to read from/write in the device (Refer to the following table for available device types) AVAILABLE DEVICE TYPES AI / AO 32 bit AI / AO 16 bit DI / DO 32 bit DI / DO 16 bit SD: Special Register SD: Special Register SM: Special relay SM: Special relay D: Data Register D: Data Register X: Input X: Input W: Link Register W: Link Register Y: Output Y: Output TN: Timer, Current value TN: Timer, Current value M: Internal relay M: Internal relay STN: Retentive timer, Current value STN: Retentive timer, Current value L: Latch relay L: Latch relay CN: Counter, Current value CN: Counter, Current value F: Annunciator F: Annunciator SW, Link special Register SW, Link special Register V: Edge relay V: Edge relay Z: Index Register Z: Index Register B: Link relay B: Link relay R: File Register R: File Register ---- S: STEP RELAY ZR: File Register ZR: File Register TS: Timer, Contact TS: Timer, Contact RD: Module refresh Register ---- TC: Timer, Coil TC: Timer, Coil LTS: Long timer, Contact ---- LTC: Long timer, Coil ---- STS: Retentive timer, Contact STS: Retentive timer, Contact STC: Retentive timer, Coil STC: Retentive timer, Coil LSTS: Long retentive timer, Contact ---- LSTC: Long retentive timer, Coil ---- CS: Counter, Contact CS: Counter, Contact CC: Counter, Coil CC: Counter, Coil LCS: Long counter, Contact LCS: Long counter, Contact LCC: Long counter, Coil LCC: Long counter, Coil SB: Link special relay SB: Link special relay Max. 16 points of analog input/output and max. 16 points of digital input/output can be allocated per a virtual module. Set the data allocation to 16 for the slot with the virtual analog input/output module, and set 1 for the slot with virtual digital input/output module by data allocation mode of the R3 Interface module. Note: Numbers of transmittable data is limited by number of channel and virtual module. R3-GSLMP1 can transmitted max. 128 channels or 16 virtual modules. Even though the total number of channels is less than 128, if the total number of virtual modules is 16, number of channel cannot be increased. Do not mount any modules in the slots which are occupied by virtual modules. If a real I/O module is mounted in the slot, an internal bus error occurs and the ERR LED turns on. Max. 16 real I/O modules and virtual modules are available. The R3 interface module can not read the data for more than 16 modules. Details are explained in “■ Number of the modules and the address allocation” on the next page. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |