Back Button MAX4995A/AF/AL Datasheet HTML 6Page - Maxim Integrated Products MAX4995A/AF/AL Datasheet HTML 7Page - Maxim Integrated Products MAX4995A/AF/AL Datasheet HTML 8Page - Maxim Integrated Products MAX4995A/AF/AL Datasheet HTML 9Page - Maxim Integrated Products MAX4995A/AF/AL Datasheet HTML 10Page - Maxim Integrated Products MAX4995A/AF/AL Datasheet HTML 11Page - Maxim Integrated Products MAX4995A/AF/AL Datasheet HTML 12Page - Maxim Integrated Products MAX4995A/AF/AL Datasheet HTML 13Page - Maxim Integrated Products MAX4995A/AF/AL Datasheet HTML 14Page - Maxim Integrated Products  
Zoom Inzoom in Zoom Outzoom out
 10 / 14 page
background image
Detailed Description
The MAX4995A/MAX4995AF/MAX4995AL/MAX4995B/
MAX4995C programmable current-limit switches operate
from +1.7V to +5.5V and provide internal current limiting
adjustable from 50mA to 600mA. These devices feature
a fixed blanking time and a FLAG output that notifies the
processor when a fault condition is present.
Programmable Current Limit
A resistor from SETI to GND programs the current limit for
the switch (see the Setting the Current Limit section). If the
output current exceeds the current limit for a time equal
to or longer than tBLANK, the output flag asserts and the
MAX4995A/MAX4995AF/MAX4995AL enter the autoretry
mode. The MAX4995B latches off the switch, and the
MAX4995C enters the continuous current-limit mode.
Autoretry (MAX4995A/MAX4995AF/
MAX4995AL)
When the forward current reaches the current-limit thresh-
old, the tBLANK timer begins counting (Figure 2). FLAG
asserts if the overcurrent-limit condition is present for
tBLANK. The timer resets if the overcurrent condition
disappears before the blanking time (tBLANK) has elapsed.
A retry time delay (tRETRY) starts immediately after the
blanking time has elapsed and during that time, the switch
latches off. At the end of tRETRY, the switch turns on
again. If the fault still exists, the cycle repeats. If the fault
has been removed, the switch stays on. During this cycle,
FLAG
stays low. In autoretry if the thermal power rating of
the package is exceeded, the MAX4995A/MAX4995AF/
MAX4995AL go into thermal shutdown.
The autoretry feature saves system power in case of an
overcurrent or short-circuit condition. During tBLANK time
when the switch is on, the supply current is held at the
current limit. During time tRETRY when the switch is off,
the current through the switch is zero. Thus, the average
output current is much less than the programmed current
limit. Calculate the average output current using the fol-
lowing equation:
ILOAD = ILIM [tBLANK/(tBLANK + tRETRY)]
With a typical tBLANK = 16.3ms and typical tRETRY =
524ms, the duty cycle is 3%, resulting in a 97% power
savings over the switch being on the entire time.
Latchoff (MAX4995B)
When the forward current reaches the current-limit
threshold, the tBLANK timer begins counting (Figure 3).
FLAG
asserts if an overcurrent-limit condition is present
for greater than tBLANK time. The timer resets if the over-
current condition disappears before tBLANK has elapsed.
The switch turns off if the overcurrent condition continues
beyond the blanking time. Reset the switch by either tog-
gling the control logic (ON) or cycling the input voltage. If
the thermal power rating of the package is exceeded dur-
ing tBLANK, the MAX4995B goes into thermal shutdown.
Continuous Current Limit (MAX4995C)
When the forward current reaches the forward currentlimit
threshold, the MAX4995C limits the output current to the
programmed current limit. FLAG asserts if the current limit
is present for tBLANK and deasserts when the overload
condition is removed. In this mode, if the thermal power
rating of the package is exceeded, the MAX4995C goes
into thermal shutdown.
Switch-On/Off Control
The ON input for the MAX4995_/MAX4995AF and ON
input for the MAX4995AL control the switch; see Table 1.
Toggle ON for the MAX4995B to reset the fault condition
once the short current is detected and the device shuts
down.
Reverse-Current Protection
The MAX4995 features a reverse-current protection
circuit that limits the backflow current to 10μA when the
output voltage exceeds the input voltage by 110mV (typ).
The switch turns off and FLAG asserts without waiting for
tBLANK to elapse. The switch turns back on and FLAG
deasserts when the output voltage drops below the
detecting threshold by 10mV (typ).
Table 1. Switch Truth Table
MAX4995_/
MAX4995AF
MAX4995AL
SWITCH
STATUS
ON
ON
0
1
Off
1
0
On
MAX4995A/AF/AL/
MAX4995B/MAX4995C
50mA to 600mA Programmable
Current-Limit Switches
www.maximintegrated.com
Maxim Integrated │ 10



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com