21 / 36 page ![]() Tripath Technology, Inc. – Preliminary Technical Information 21 TCD6000 – Rev. 1.0/09.04 Channel Volume Addr Register Name D7 D6 D5 D4 D3 D2 D1 D0 25h Channel 1 Volume V17 V16 V15 V14 V13 V12 V11 V10 26h Channel 2 Volume V27 V26 V25 V24 V23 V22 V21 V20 27h Channel 3 Volume V37 V36 V35 V34 V33 V32 V31 V30 28h Channel 4 Volume V47 V46 V45 V44 V43 V42 V41 V40 29h Channel 5 Volume V57 V56 V55 V54 V53 V52 V51 V50 2Ah Channel 6 Volume V67 V66 V65 V64 V63 V62 V61 V60 Default 0 0 0 0 0 0 0 0 The TCD6000 has 6 channel volume registers, one for each channel. The 8-bit value in each register represents the volume loudness for the corresponding channel. The least significant bit, D0, represents a volume increment of 0.5dB. Therefore the total range available is 128dB. Maximum volume is achieved when the volume register contains a value of FFh, and no sound is heard if its value is 00h. In addition, a “coarse gain” adjustment (1X, 2X, 4X, and 8X) is made possible by programming the Volume Change Control Register. Volume Ramp Rate Addr Register Name D7 D6 D5 D4 D3 D2 D1 D0 2Bh Volume Ramp Rate RR7 RR6 RR5 RR4 RR3 RR2 RR1 RR0 Default 1 0 0 0 0 0 0 0 The TCD6000 can be programmed to have volume changes take effect immediately or be ramped at a predefined rate for all channels. If the Volume Ramp Enable bit is set, the Volume Ramp Rate Register defines the ramp rate. Although the Volume Control Registers define the channel volume within an accuracy of ½ dB, volume will be ramped internally in 1/8 dB steps when ramping is enabled. The number entered into the Volume Ramp Rate Register can be from 0 (00h) to 255 (FFh). If the number entered is N, the time delay between two consecutive 1/8 dB volume increments is equal to: N x (4 periods of LRCK) As an example, if N = 100 and data samples are coming in at a 44.1kHz rate, the period of LRCK is 22.67usec. The delay between two consecutive 1/8 dB volume increments is: 100 x 4 x 22.67usec = 9068usec Therefore if the volume change is 60 dB (480 increments of 1/8 dB), the total ramp time will be: 480 x 9068usec = 4.32 second Channel Mute Control Addr Register Name D7 D6 D5 D4 D3 D2 D1 D0 2Ch Channel Mute Control M6 M5 M4 M3 M2 M1 HM AM Default 0 0 0 0 0 0 1 0 The TCD6000 has 3 different Mute functions: Soft-Mute, Hard-Mute, and Auto-Mute. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |