92 / 98 page ![]() 74 Receiver Troubleshooting Section 17-4 17-4 Receiver Troubleshooting If the yellow INTERLOCK LED is blinking: 1. Check the configuration for External Device Monitoring. If EDM is inactive (via receiver dip switch), the input (red wire) must be connected to system ground. If EDM is active, the input must be connected to the normally closed contacts of the control relays of the guarded machine or the monitor terminal of the safety relay unit. Please refer to SECTION 11 Connection to the Machine Control Circuit for an example. 2. Make sure both selector switches in the receiver endcap have been set properly and identically. Please refer to chapter 7-2 Operating mode selec- tion for further information. 3. Verify the power supply is within the specified limits (+24V ±20%). 4. Verify the light curtain is properly connected to the control relays of the guarded machine. If the light curtain is not intended to be connected to control relays, see SECTION 12 Muting for further information. 5. Verify the control relays are within operating limits of the safety outputs. 6. Verify the cable lengths from the light curtain to the control relays are within specified limits. 7. If this does not solve the problem, please contact your local Omron distrib- utor or the European Repair Center. 17-5 Receiver Error Codes Code Group Error Code Description of Error Code Corrective Action Needed Configuration Switch Faults 21 Invalid mode selection setting Verify switch setting, see user manual 22 Configuration switch settings changed dur- ing operation Verify switch setting, see user manual 23 Configuration switch settings do not match Verify switch setting, see user manual 24 Corrupted EEPROM configuration Reset the system configuration to factory defaults 26 Invalid scan code setting Verify switch setting, see user manual Safety Output (OSSD) Faults 31 Safety outputs 1&2 are shorted together Check and correct wiring of safety outputs 1 and 2 32 Safety output 1 is shorted to power Check and correct wiring of safety outputs 1 33 Safety output 2 is shorted to power Check and correct wiring of safety outputs 2 34 Safety output 1 is shorted to ground Check and correct wiring of safety outputs 1 35 Safety output 2 is shorted to ground Check and correct wiring of safety outputs 2 EDM Faults 41 EDM circuit did not open before transition to MACHINE RUN state Check and correct EDM wiring 42 EDM circuit did not open after transition to MACHINE RUN state Check and correct EDM wiring 43 EDM circuit was in wrong state during power-up Check and correct EDM wiring 44 EDM fault at power-up Check start input wire or EDM function selection Controller Fault 50 Control logic fault Please contact your local Omron distributor or the European Repair Center Setup Error 60 Possible crosstalk Check and correct scan code setting Muting Faults 70 General muting fault Check wiring of unused mute sensors 71 Mute module enable and configuration required: Check mounting of mute sensors for correct sequence 74 Mute lamp burned out or not connected Check status of mute lamp |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |