3 / 8 page ![]() 3 MFL SERIES 65 WATT DC/DC CONVERTERS ® Electrical Characteristics: –55°C to +125°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified. DUAL OUTPUT MODELS MFL2805D MFL2812D MFL2815D PARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS OUTPUT VOLTAGE Tc = 25°C +VOUT 4.95 5.00 5.05 11.88 12.00 12.12 14.85 15.00 15.15 VDC –VOUT 4.92 5.00 5.08 11.82 12.00 12.18 14.77 15.00 15.23 OUTPUT CURRENT1 EACH OUTPUT 0 — 7 0 — 3.5 0 — 3.03 A VIN = 16 TO 40 VDC TOTAL OUTPUT 0 — 10 0 — 5 0 — 4.34 OUTPUT POWER VIN = 16 TO 40 VDC 0 — 50 0 — 60 0 — 65 W OUTPUT RIPPLE VOLTAGE +/– VOUT 10 kHz - 2 MHz — 50 100 — 50 120 — 50 150 mV p-p LINE REGULATION +VOUT —0 50 —0 50 — 0 50 mV VIN = 16 TO 40 VDC –VOUT —25 100 —25 100 — 25 100 LOAD REGULATION +VOUT —0 50 — 10 100 — 10 100 mV NO LOAD TO FULL –VOUT —25 100 —50 120 — 50 150 CROSS REGULATION SEE NOTE 2 — 5 8 — 2 4 — 2 4 % Tc = 25°C SEE NOTE 3 — 3 6 — 2 4 — 2 4 INPUT VOLTAGE CONTINUOUS 16 28 40 16 28 40 16 28 40 VDC NO LOAD TO FULL TRANSIENT4 50 ms. 0 — 50 0 —50 0 — 50 V INPUT CURRENT NO LOAD — 50 120 — 50 100 — 50 100 mA Tc = 25°C FULL LOAD — — — — 2.80 — — 3.00 A INHIBITED - INH1 — 9 14 — 9 14 — 9 14 mA INHIBITED - INH2 — 35 70 — 35 70 — 35 70 INPUT RIPPLE CURRENT 10 kHz - 10 MHz — 15 50 — 15 50 — 15 50 mA p-p EFFICIENCY 25°C Tc BALANCED LOAD 77 80 — 83 86 — 84 87 — % LOAD FAULT5 POWER DISSIPATION Tc = 25°C SHORT CIRCUIT — 12.5 16 — 10 14 — 10 14 W RECOVERY — 1.5 4.0 — 1.5 4.0 — 1.5 4.0 ms STEP LOAD 50 %–100%– 50% LOAD RESPONSE ± VOUT TRANSIENT — 250 350 — 450 600 — 500 600 mV pk RECOVERY6 — 1.5 3.0 — 1.5 3.0 — 1.5 3.0 ms STEP LINE 16 – 40 – 16 VIN RESPONSE ± VOUT TRANSIENT7 — 250 300 — 250 400 — 250 400 mV pk RECOVERY6 — 200 300 — 200 300 — 200 300 µs START–UP DELAY — 3.5 6 — 3.5 6 — 3.5 6 ms OVERSHOOT — 0 25 — 0 50 — 0 50 mV p Notes 1. Up to 70% of the total output power is available from either output providing the opposite output is simultaneously carrying 30% of the total power. 2. Effect on the negative output under the following conditions: +Pout 30% to 70%; –Pout 70% to 30% 3. Effect on the negative output under the following conditions: +Pout 50%; –Pout 10% to 50% 4. Unit will shut down above approximately 45V but will be undamaged and will restart when voltage drops into normal range. 5. Indefinite short circuit protection not guaranteed above 125°C case. 6. Recovery time is measured from application of the transient to point at which Vout is within 1% of final value. 7. Transition time ≥ 10 µs. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |