15 / 21 page ![]() 3 MHF+ SERIES TRIPLE 15 WATT DC/DC CONVERTERS Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified. MHF+28512T MHF+28515T PARAMETER CONDITION MIN TYP MAX MIN TYP MAX UNITS OUTPUT VOLTAGE MAIN 4.95 5.0 5.05 4.925 5.0 5.05 + AUXILIARY 11.64 12.0 12.36 14.55 15.0 15.45 VDC – AUXILIARY 11.64 12.0 12.36 14.55 15.0 15.45 OUTPUT CURRENT1 MAIN 0 — 1.5 0 — 1.5 + AUXILIARY —— 0.416 —— 0.333 A – AUXILIARY —— 0.416 —— 0.333 TOTAL —— 2.125 —— 2.0 OUTPUT POWER2 MAIN —— 7.5 —— 7.5 + AUXILIARY —— 5 —— 5 W – AUXILIARY —— 5 —— 5 TOTAL —— 15 —— 15 OUTPUT RIPPLE 10 kHz to 2 MHz MAIN — 20 75 — 20 75 VOLTAGE 10 kHz to 2 MHz ± AUXILIARY — 30 90 — 30 112 mV p-p LINE REGULATION3 MAIN — 25 75 — 25 75 mV VIN = MIN. TO MAX. ±AUXILIARY — 120 240 — 150 300 LOAD REGULATION3, 4 MAIN — 25 60 — 25 60 mV ± AUXILIARY — 120 240 — 150 300 CROSS REGULATION5 – AUXILIARY —— 1200 —— 1500 mV INPUT VOLTAGE CONTINUOUS 16 28 48 16 28 48 VDC TRANSIENT 120 ms —— 80 —— 80 V INPUT CURRENT NO LOAD3 — 20 35 — 20 35 FULL LOAD — 705 724 — 705 724 mA INHIBITED3 — 35 — 35 INPUT RIPPLE CURRENT 10 kHz to 10 MHz — 20 50 — 20 50 mA p-p EFFICIENCY 74 76 — 74 76 — % LOAD FAULT6 POWER DISSIPATION MAIN3 —— 12 —— 12 W ±AUXILIARY —— 12 —— 12 STEP LOAD TRANSIENT RESPONSE3, 7, 8 MAIN —— 850 —— 850 mV pk ± AUXILIARY —— 750 —— 750 RECOVERY MAIN — 58 — 58 ms RECOVERY ±AUX. — 23 — 23 START-UP3, DELAY EACH OUTPUT — 10 25 — 10 25 ms Notes 1. The sum of the 12 volt auxiliary output currents may not exceed 625 mA. The sum of the 15 volt auxiliary output currents may not exceed 500 mA. 2. The sum of the auxiliary output power may not exceed 7.5 watts. 3. Case temperature –55°C to +125°C. 4. Load regulation for the +5 is specified at 0.0 to 1.5 A with the aux. both held at 3.76 W (313 mA for the ±12, 250 mA for the ±15). Load regulation for the aux. is specified as both aux. from 0.0 to 3.76 W (313 mA for ±12, 250 mA for ±15) at the same time with the +5 held at 1.5 A. 5. Cross regulation only occurs between the two auxiliaries and is measured on –aux. +5 is held constant at 1.0 A. Cross regulation is specified for two conditions: Negative aux.= 3.76 W; positive aux.= 0.37 W to 3.76 W. Negative aux. = 0.37 W to 3.76 W; positive aux. = 3.76 W. 6. Load fault = <0.05 Ω. 7. Transition time is 2 – 10 µs. 8. Time to settle to within 1% of Vout final value. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |