| Electronic Components Datasheet Search |
|
PLA15F Datasheet(PDF) 13 Page - COSEL CO., LTD. |
|
|
|||||||||||||||||||||||||||||
PLA15F Datasheet(HTML) 13 Page - COSEL CO., LTD. |
|
13 / 14 page ![]() PLA-14 PLA600F AC-DC Power Supplies Enclosed Type PL A 600 F -O -O Ordering information R 1 2 3 4 5 6 SPECIFICATIONS MODEL PLA600F-12 PLA600F-15 PLA600F-24 PLA600F-36 PLA600F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *4 CURRENT[A] ACIN 100V 6.7typ (Io=90%) ACIN 115V 6.5typ (Io=100%) ACIN 230V 3.2typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 81typ (Io=90%) 81typ (Io=90%) 84typ (Io=90%) 85typ (Io=90%) 85typ (Io=90%) ACIN 115V 81typ (Io=100%) 81typ (Io=100%) 84typ (Io=100%) 85typ (Io=100%) 85typ (Io=100%) ACIN 230V 84typ (Io=100%) 84typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) POWER FACTOR ACIN 100V 0.98typ (Io=90%) ACIN 115V 0.98typ (Io=100%) ACIN 230V 0.95typ (Io=100%) INRUSH CURRENT[A] ACIN 100V 20/40typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) ACIN 115V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) ACIN 230V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) LEAKAGE CURRENT[mA] 1.5max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 12 15 24 36 48 CURRENT[A] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) ACIN 115V-264V 50 40 25 16.7 12.5 WATTAGE[W] ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) ACIN 115V-264V 600 600 600 601.2 600 LINE REGULATION[mV] *8 48max 60max 96max 144max 192max LOAD REGULATION[mV] *8 100max 120max 150max 150max 300max RIPPLE[mVp-p] *1 0 to +50C 120max 120max 120max 150max 150max -20 to 0C 160max 160max 160max 160max 400max RIPPLE NOISE[mVp-p] *1 0 to +50C 150max 150max 150max 200max 200max -20 to 0C 180max 180max 180max 240max 500max TEMPERATURE REGULATION[mV] 0 to +50C 120max 150max 240max 360max 480max -20 to +50C 180max 180max 290max 440max 600max DRIFT[mV] *2 48max 60max 96max 144max 192max START-UP TIME[ms] 300typ (ACIN 115V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 115V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 OUTPUT VOLTAGE SETTING[V] 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OVERVOLTAGE PROTECTION[V] 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 OPERATING INDICATION LED (Green) REMOTE SENSING Optional (Option -W) REMOTE ON/OFF Optional (Required external power source. Option -R) ISOLATION INPUT-OUTPUT RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) OUTPUT RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) OUTPUT-RC *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) ENVIRONMENT OPERATINGTEMP.,HUMID.AND ALTITUDE *5 -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR *10 Complies with IEC61000-3-2 class A 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *7 C : with Coating G : Low leakage current V : External potentiometer for output voltage adjustment U : Low input voltage stop (Complies with SEMI F-47) W: Parallel operation, LV alarm Remote sensing R : Remote on/off (Required external power source) F4: Low speed fan T2: Horizontal terminal block (non-screw-hold type) See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. *Please consider “PJA600F-5” about 5V output. Example recommended EMI/EMC filter NAC-16-472 *A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. High voltage pulse noise type : NAP series Low leakage current type : NAM series April 17, 2018 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |