| Electronic Components Datasheet Search |
|
M41T94 Datasheet(PDF) 20 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M41T94 Datasheet(HTML) 20 Page - STMicroelectronics |
|
20 / 40 page ![]() Clock operations M41T94 20/40 4.3 Setting Alarm clock registers Address locations 0Ah-0Eh contain the Alarm settings. The Alarm can be configured to go off at a prescribed time on a specific month, date, hour, minute, or second, or repeat every year, month, day, hour, minute, or second. It can also be programmed to go off while the M41T94 is in the battery back-up to serve as a system wake-up call. Bits RPT5-RPT1 put the Alarm in the Repeat mode of operation. Table 5 on page 20 shows the possible configurations. Codes not listed in the table default to the once per second mode to quickly alert the user of an incorrect Alarm setting. When the clock information matches the Alarm clock settings based on the match criteria defined by RPT5-RPT1, the AF (Alarm Flag) is set. If AFE (Alarm Flag Enable) is also set, the Alarm condition activates the IRQ/FT/OUT pin. Note: If the address pointer is allowed to increment to the Flag register address, an Alarm condition will not cause the Interrupt/Flag to occur until the address pointer is moved to a different address. It should also be noted that if the last address written is the “Alarm Seconds,” the address pointer will increment to the Flag address, causing this situation to occur. To disable the Alarm, write '0' to the Alarm date register and to RPT1–5. The IRQ/FT/OUT output is cleared by a READ to the Flags register. This READ of the Flags register will also reset the Alarm Flag (D6; register 0Fh). See Figure 11 on page 21. The IRQ/FT/OUT pin can also be activated in the Battery Back-up mode. The IRQ/FT/OUT will go low if an Alarm occurs and both ABE (Alarm in Battery Back-up mode Enable) and AFE are set. The ABE and AFE bits are reset during power-up, therefore an Alarm generated during power-up will only set AF. The user can read the Flag register at system boot-up to determine if an Alarm was generated while the M41T94 was in the deselect mode during power-up. Figure 12 on page 21 illustrates the Back-up mode Alarm timing. Table 5. Alarm Repeat mode RPT5 RPT4 RPT3 RPT2 RPT1 Alarm setting 11 111 Once per Second 11 110 Once per Minute 11 100 Once per Hour 11 000 Once per Day 10 000 Once per Month 0 0 0 0 0 Once per Year |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |