| Electronic Components Datasheet Search |
|
LSM6DSV320X Datasheet(PDF) 35 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
LSM6DSV320X Datasheet(HTML) 35 Page - STMicroelectronics |
|
35 / 212 page ![]() 6.4 Gyroscope power modes In the LSM6DSV320X, the gyroscope can be configured in six different operating modes: power-down mode, sleep mode, low-power mode, high-performance mode, high-accuracy ODR mode, and ODR-triggered mode. The operating mode selected depends on the value of the OP_MODE_G_[2:0] bits in CTRL2 (11h). If the value of the OP_MODE_G_[2:0] bits is 000 (default), high-performance mode is valid for all ODRs (from 7.5 Hz up to 7.68 kHz). Low-power mode is available for lower ODRs (7.5 Hz, 15 Hz, 30 Hz, 60 Hz, 120 Hz, 240 Hz) and it is enabled by setting the OP_MODE_G_[2:0] bits to 101. High-accuracy ODR mode is available for ODR values from 15 Hz up to 7.68 kHz and it is enabled by setting the OP_MODE_G_[2:0] bits to 001. Refer to Section 6.5: High-accuracy ODR mode for more details. ODR-triggered mode is available for ODR values from 15 Hz up to 7.68 kHz and it is enabled by setting the OP_MODE_XL_[2:0] bits to 011. Refer to Section 6.6: ODR-triggered mode for more details 6.5 High-accuracy ODR mode High-accuracy ODR (HAODR) mode can be enabled to reduce the part-to-part output data rate variation. It supports both the low-g, high-g accelerometers and the gyroscope. When this mode is used for one sensor (accelerometers or gyroscope), the other sensor also has to be configured in high-accuracy ODR (HAODR) mode. The main high-accuracy ODR features are: • Noise level is aligned with high-performance mode • The power consumption in HAODR mode depends on the selected ODR and on the enabled sensors. As an example, at ODR = 960 Hz in combo mode (low-g accelerometer + gyroscope) it increases 20 μA (typical) compared to high-performance mode. Refer to the application note for more details. • The UI channel bandwidth can be selected through the gyroscope LPF1 and accelerometer HPF/LPF2 filters. • When HAODR mode is enabled, it is applied to the UI low-g, high-g accelerometers, UI gyroscope, EIS gyroscope, and temperature. It is not applied to the OIS accelerometer/gyroscope channels. Note: HAODR mode has to be enabled / disabled when the device is in power-down mode. When HAODR mode is enabled, four different sets of ODRs are supported based on the configuration of the HAODR_SEL_[1:0] bitfield in the HAODR_CFG (62h) register, as shown in the table below. Note: High-accuracy ODR mode is not compatible with the activity/inactivity functionality (motion/stationary can be used). Table 22. Accelerometer and gyroscope ODR selection in high-accuracy ODR mode ODR_XL_[3:0] ODR_G_[3:0] ODR [Hz] HAODR_SEL_[1:0] = 00 ODR [Hz] HAODR_SEL_[1:0] = 01 ODR [Hz] HAODR_SEL_[1:0] = 10 ODR [Hz] HAODR_SEL_[1:0] = 11 0000 Power-down Power-down Power-down Power-down 0001 Reserved Reserved Reserved Reserved 0010 Reserved Reserved Reserved Reserved 0011 15 15.625 12.5 13 0100 30 31.25 25 26 0101 60 62.5 50 52 0110 120 125 100 104 0111 240 250 200 208 1000 480 500 400 417 1001 960 1000 800 833 1010 1920 2000 1600 1667 1011 3840 4000 3200 3333 1100 7680 8000 6400 6667 Others Reserved Reserved Reserved Reserved LSM6DSV320X Functionality DS14623 - Rev 1 page 35/212 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |