Electronic Components Datasheet Search
  British  ▼
ALLDATASHEET.CO.UK

X  

AP61402Q Datasheet(PDF) 13 Page - Diodes Incorporated

Part # AP61402Q
Description  2.3V TO 5.5V INPUT, 4A AUTOMOTIVE-COMPLIANT SYNCHRONOUS BUCK CONVERTER
PDF  18 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  DIODES [Diodes Incorporated]
Direct Link  http://www.diodes.com
Logo DIODES - Diodes Incorporated

AP61402Q Datasheet(HTML) 13 Page - Diodes Incorporated

Back Button AP61402Q Datasheet HTML 9Page - Diodes Incorporated AP61402Q Datasheet HTML 10Page - Diodes Incorporated AP61402Q Datasheet HTML 11Page - Diodes Incorporated AP61402Q Datasheet HTML 12Page - Diodes Incorporated AP61402Q Datasheet HTML 13Page - Diodes Incorporated AP61402Q Datasheet HTML 14Page - Diodes Incorporated AP61402Q Datasheet HTML 15Page - Diodes Incorporated AP61402Q Datasheet HTML 16Page - Diodes Incorporated AP61402Q Datasheet HTML 17Page - Diodes Incorporated Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 18 page
background image
AP61402Q
Document number: DS47061 Rev. 3 - 2
13 of 18
www.diodes.com
September 2025
© 2025 Copyright Diodes Incorporated. All Rights Reserved.
AP61402Q
Application Information
Constant-On-Time Control
The Constant-On-Time control architecture allows for fast transient response and requires no loop compensation, which reduces external component
count and reduces design complexity.
The COT control relies on a fixed switch on time to regulate the output. The on-time of the high-side switch can be estimated as:
tON = 500ns x (VOUT/VIN)
The AP61402Q has a fixed minimum off-time of 60ns, which can prevent the inductor current runaway during load transient.
Undervoltage Lockout (UVLO) Circuit
When the VIN drops lower than the UVLO detector threshold (2V typ), the UVLO circuit starts to operate, VREF stops, and with the high-side and low-
side switch turned “OFF”. As a result, VOUT drops according to the COUT capacitance value and the load. When the VIN is rising higher than UVLO
released voltage (2.15V typ), the IC will restart the operation.
Current Limit Protection
The AP61402Q typically has a 4A high-side switch current limit to 6A. When the current flowing into high-side switch reaches the current limit
threshold, the AP61402Q will enter cycle by cycle current limit mode until the current drops. Also, a cycle-by-cycle valley current detect circuit is
implemented for current limit. The switch current is monitored during the low-side switch on state; if the monitored current is above the current
threshold, the converter maintains low-side switch on until the current level becomes threshold level or lower.
Short-Circuit Protection and Recovery
When the AP61402Q output node is shorted to GND and VFB drops under 0.36V, it will enter hiccup mode to lower power loss. If the short circuit is
removed, and VFB rises over 0.36V, the AP61402Q recovers to normal operation again.
Overtemperature Protection
The internal thermal temperature protection circuitry is provided to protect the integrated circuit if the maximum junction temperature is exceeded.
When the junction temperature exceeds +160°C, it shuts down the internal control circuit and switches. The AP61402Q will restart automatically
under the control of soft-start circuit when the junction temperature decreases to +130°C.
Enable
When disabled, the device shutdown supply current is only 0.1μA. When applying a voltage greater than the EN logic-high threshold (typical 0.91V,
rising), the AP61402Q enables all functions, and the device initiates the soft-start phase. The AP61402Q has a built-in 0.5ms soft-start time to
prevent output voltage overshot and inrush current. When the EN voltage falls below its logic-low threshold (typical 0.83V, falling), the internal SS
voltage discharges to ground and device operation is disabled.
PWM, Continuous Conduction Mode Operation
The device operates in PFM when a logic-high voltage is applied to the EN pin greater than VIN – 200mV. The device operates in PWM regardless
of output load when a logic-high voltage is applied to the EN pin less than VIN – 200mV. Connect a resistive divider 100kΩ/200kΩ from EN to GND,
and the device enters PWM and operates with a constant switching frequency over the entire load range, even at very light loads. This allows
predictable operational frequency across loading and avoids potential interference to other sensitive circuitries.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com