  RACPRO1-T480/48 Datasheet HTML 1Page - Recom International Power RACPRO1-T480/48 Datasheet HTML 2Page - Recom International Power RACPRO1-T480/48 Datasheet HTML 3Page - Recom International Power RACPRO1-T480/48 Datasheet HTML 4Page - Recom International Power RACPRO1-T480/48 Datasheet HTML 5Page - Recom International Power RACPRO1-T480/48 Datasheet HTML 6Page - Recom International Power RACPRO1-T480/48 Datasheet HTML 7Page - Recom International Power RACPRO1-T480/48 Datasheet HTML 8Page - Recom International Power RACPRO1-T480/48 Datasheet HTML 9Page - Recom International Power Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 11 page
background image
Technical Data Sheet
AC/DC Converter
Rev.: 0-2025
Page 2
copyright © RECOM Power GmbH, all rights reserved
www.recom-power.com
480W ◊ Input: 3AC 400-480V
RACPRO1-T480 Series ◊ DIN-Rail Power Supply
BASIC CHARACTERISTICS (measured @ TAMB= 25°C, 3AC 400VAC full load and after warm-up unless otherwise stated)
Parameter
Condition
Min.
Typ.
Max.
Nominal Input Voltage
50/60Hz
400VAC
480VAC
Operating Range (3)
3 phase operation (4)
320VAC
575VAC
2 phase operation, max. POUT= 340W
350VAC
480VAC
DC input
refer to
„Connections for DC-operation“
continuous
450VDC
815VDC
10s max.
850VDC
Turn-on Voltage
prevents switching on during 1AC operation
310VAC
DC operation
440VDC
Turn-off Voltage
AC operation
280VAC
DC operation
395VDC
Input Current
AC operation
400VAC
3x 0.8A
480VAC
3x 0.7A
DC operation
500VDC
1.0A
Inrush Current
3AC 400VAC, cold start
10A
No Load Power Consumption
3AC 400VAC
RACPRO1-T480/24
1.9W
3W
RACPRO1-T480/48
2.4W
3AC 480VAC
RACPRO1-T480/24
2W
RACPRO1-T480/48
2.9W
Input Frequency Range
47Hz
63Hz
Nominal Output Voltage (factory set)
RACPRO1-T480/24
24VDC
RACPRO1-T480/48
48VDC
Minimum Load
0%
Power Factor
full load
0.92
Start-up time
2 & 3 phase operation, 400VAC
98ms
112ms
Rise time
3.5ms
7ms
Hold-up time
400VAC
15ms
480VAC
30ms
Internal Operating Frequency
83kHz
Ripple and Noise
20MHz bandwidth
1% of nom V
OUT
Note3: The products were submitted for safety files at AC and DC-Input operation. (350V-575VAC and 450-600VDC)
If input voltage is >500VDC consider an external fuse according to applicable standards.
2phase operation is not included in the safety approvals. Additional tests might be necessary when the complete application has to be approved
according to UL 62368-1, 61010-1 and UL 61010-2-201.
Note4: Output power derating for Line-input of less than 3AC 350VAC (derate linearly from 100% at 350VAC to 90% at 3AC 320VAC)
RACPRO1-T
L1
L3
+VOUT
-VOUT
+VIN
-VIN
RACPRO1-T
L1
L3
+VOUT
-VOUT
+VIN
-VIN
1 DC-source
2 DC-sources
Connections for DC-operation



Html Pages

1 2 3 4 5 6 7 8 9 10 11


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com