Back Button RACPRO1-T960/48 Datasheet HTML 3Page - Recom International Power RACPRO1-T960/48 Datasheet HTML 4Page - Recom International Power RACPRO1-T960/48 Datasheet HTML 5Page - Recom International Power RACPRO1-T960/48 Datasheet HTML 6Page - Recom International Power RACPRO1-T960/48 Datasheet HTML 7Page - Recom International Power RACPRO1-T960/48 Datasheet HTML 8Page - Recom International Power RACPRO1-T960/48 Datasheet HTML 9Page - Recom International Power RACPRO1-T960/48 Datasheet HTML 10Page - Recom International Power RACPRO1-T960/48 Datasheet HTML 11Page - Recom International Power  
Zoom Inzoom in Zoom Outzoom out
 7 / 11 page
background image
Technical Data Sheet
AC/DC Converter
Rev.: 0-2025
Page 7
copyright © RECOM Power GmbH, all rights reserved
www.recom-power.com
960W ◊ Input: 3AC 400-480V
RACPRO1-T960 Series ◊ DIN-Rail Power Supply
Boost Power
(400V-480VAC or 500VDC; -40°C to +60°C max.)
IOUT
Easy Fuse
tripping
≤6s
≤20ms
60s
150%
250%
100%
Time
ENVIRONMENTAL (measured @ TAMB= 25°C, 3AC 400VAC full load and after warm-up unless otherwise stated)
SAFETY & CERTIFICATIONS
Certificate Type (Safety)
Report Number
Standard
Audio/Video, information and communication technology equipment - Part 1: Safety requirements (CB) 24TH0201_62368
-1_0
IEC62368-1:2018 3rd Edition
Audio/Video, information and communication technology equipment - Part 1: Safety requirements
EN IEC 62368-1:2020+A11:2020
Audio/Video, information and communication technology equipment - Part 1: Safety requirements
pending
UL62368-1:2019 3rd Edition
CAN/CSA-C22.2 No. 62368-1-19 3rd Edition
Electrical Equipment For Measurement, Control, and Laboratory Use; Part 1: General Requirements (CB) 4TH0201_61010
-1_0
IEC61010-1:2010+A1:2016 3rd Edition
Electrical Equipment For Measurement, Control, and Laboratory Use; Part 1: General Requirements
EN61010-1:2010+A1:2019
Electrical Equipment For Measurement, Control, and Laboratory Use; Part 1: General Requirements
pending
UL61010-1:2012 3rd Edition
CAN/CSA-C22.2 No. 61010-1-12 3rd Edition
Electrical Equipment For Measurement, Control, and Laboratory Use; Part 2-201:
Particular requirements for control equipment (CB)
24TH0201_61010
-2-201_0
IEC61010-2-201:2017 2nd Edition
Electrical Equipment For Measurement, Control, and Laboratory Use; Part 2-201:
Particular requirements for control equipment
EN IEC 61010-2-201:2018
Electrical Equipment For Measurement, Control, and Laboratory Use; Part 2-201:
Particular requirements for control equipment
pending
UL61010-2-201:2018 2nd Edition
CAN/CSA-C22.2 No. 61010-2-201:2018-02-01
RoHS2
RoHS 2011/65/EU + AM2015/863
EMC Compliance according to IEC/EN61000-6-4/6-2
Condition
Standard / Criterion
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards -
Immunity standard for industrial environments
IEC/EN61000-6-2:2019
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards -
Emission standard for residential area
IEC/EN 61000-6-3:2021
ESD Electrostatic discharge immunity test
Air: ±8kV; Contact: ±6kV
IEC61000-4-2:2008, Criteria A
EN61000-4-2:2009, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
10V/m (80-1000MHz)
IEC/EN61000-4-3:2006+A2:2010, Criteria A
Fast Transient and Burst Immunity
AC Power Port: ±4kV
DC-Output Port: ±2kV
IEC/EN61000-4-4:2012, Criteria A
Surge Immunity
AC-Power Port:
L1-L2, L1-L3, L2-L3: ±2.5kV
L1-PE,L2-PE,L3-PE: ±6kV
IEC/EN61000-4-5:2014+A1:2017,
Criteria A
DC-Output Port:
Vout(+) - Vout(-), DC-OK(13-14): ±1kV
Vout(+)-PE, Vout(-)-PE: ±2kV
Immunity to conducted disturbances, induced by radio-frequency fields
10Vrms (0.15-80MHz)
IEC61000-4-6:2013, Criteria A
EN61000-4-6:2014, Criteria A
Power Magnetic Field Immunity
30A/m, 50/60Hz
EN61000-4-8:2010, Criteria A



Html Pages

1 2 3 4 5 6 7 8 9 10 11


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com