| Electronic Components Datasheet Search |
|
2000-0AV Datasheet(PDF) 2 Page - Dwyer Instruments, |
|
|
|||||||||||||||||||||||||||||
2000-0AV Datasheet(HTML) 2 Page - Dwyer Instruments, |
|
2 / 4 page ![]() MAGNEHELIC® DIFFERENTIAL PRESSURE GAGES Indicate Positive, Negative or Differential,Accurate within 1% 21 Bezel provides flange for flush mounting in panel. Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale. Precision litho-printed scale is accurate and easy to read. Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration. Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft. Pointer stops of molded rubber prevent pointer over-travel without damage. “Wishbone” assembly provides mounting for helix, helix bearings and pointer shaft. Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid. Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale. Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing cover. O-ring seal provides pressure tightness. O-ring seal for cover assures pressure integrity of case. OVERPRESSURE PROTECTION Blowout plug is comprised of a rubber plug on the rear which functions as a relief valve by unseating and venting the gage interior when over pressure reaches approximately 25 psig (1.7 bar). To provide a free path for pressure relief, there are four spacer pads which maintain 0.023˝ clearance when gage is surface mounted. Do not obstruct the gap created by these pads. The blowout plug is not used on models above 180˝ of water pressure, medium or high pressure models, or on gages which require an elastomer other than silicone for the diaphragm. The blowout plug should not be used as a system overpressure control. High supply pressures may still cause the gage to fail due to over pressurization, resulting in property damage or serious injury. Good engineering practices should be utilized to prevent your system from exceeding the ratings of any component. Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting. Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures. Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages. VELOCITY AND VOLUMETRIC FLOW UNITS Scales are available on the Magnehelic® gage that read in velocity units (FPM, m/s) or volumetric flow units (SCFM, m3/s, m3/h). Stocked velocity units with dual range scales in inches w.c. and feet per minute are shown above. For other ranges contact the factory. When ordering volumetric flow scales please specify the maximum flow rate and its corresponding pressure. Example: 0.5 in w.c. = 16,000 CFM. A-310A SERIES 2000 DWYER INSTRUMENTS, LLC | dwyer-inst.com CALIBRATION SERVICES AVAILABLE ACCESSORIES Model Description A-135 A-310A A-321 A-401 A-448 Rubber gasket for panel mounting 3-way vent valves. In applications where pressure is continuous and the Magnehelic® gage is connected by metal or plastic tubing which cannot be easily removed, we suggest using Dwyer A-310A vent valves to connect gage. Pressure can then be removed to check or re-zero the gage Safety relief valve Plastic carry case 3-piece magnet kit for mounting Magnehelic® gage directly to magnetic surface MODEL CHART Model Range, Inches of Water Model Range, PSI Model Range, MM of Water Model Range, kPa Dual Scale Air Velocity Units For use with pitot tube 2000-00N†•• 2000-00†•• 2000-0†• 2001 2002 2003 2004 2005 2006 2008 2010 2012 2015 2020 2025 2030 2040 2050 2060 2080 2100 2120 2150 2160 2180* 2250* .05-0-.2 0-.25 0-.50 0-1.0 0-2.0 0-3.0 0-4.0 0-5.0 0-6.0 0-8.0 0-10 0-12 0-15 0-20 0-25 0-30 0-40 0-50 0-60 0-80 0-100 0-120 0-150 0-160 0-180 0-250 2201 2202 2203 2204 2205 2210* 2215* 2220* 2230** 0-1 0-2 0-3 0-4 0-5 0-10 0-15 0-20 0-30 2000-6MM†•• 2000-10MM†• 2000-15MM 2000-25MM 2000-30MM 2000-50MM 2000-80MM 2000-100MM 2000-125MM 2000-150MM 2000-200MM 2000-250MM 2000-300MM 0-6 0-10 0-15 0-25 0-30 0-50 0-80 0-100 0-125 0-150 0-200 0-250 0-300 2000-0.5KPA 2000-1KPA 2000-1.5KPA 2000-2KPA 2000-2.5KPA 2000-3KPA 2000-4KPA 2000-5KPA 2000-8KPA 2000-10KPA 2000-15KPA 2000-20KPA 2000-25KPA 2000-30KPA 0-0.5 0-1 0-1.5 0-2 0-2.5 0-3 0-4 0-5 0-8 0-10 0-15 0-20 0-25 0-30 Model Range, in w.c./ Velocity F.P.M. 2000-00AV†•• 2000-0AV†• 2001AV 2002AV 2005AV 2010AV 0-.25/300-2000 0-.50/500-2800 0-1.0/500-4000 0-2.0/1000-5600 0-5.0/2000-8800 0-10/2000-12500 Model Range, CM of Water 2000-15CM 2000-20CM 2000-25CM 2000-50CM 2000-80CM 2000-100CM 2000-150CM 2000-200CM 2000-250CM 2000-300CM 0-15 0-20 0-25 0-50 0-80 0-100 0-150 0-200 0-250 0-300 Zero Center Ranges Zero Center Ranges 2300-6MM†•• 2300-10MM†• 2300-20MM†• 3-0-3 5-0-5 10-0-10 2300-1KPA 2300-2KPA 2300-2.5KPA 2300-3KPA .5-0-.5 1-0-1 1.25-0-1.25 1.5-0-1.5 Model Range, Pa Zero Center Ranges 2000-60NPA†•• 2000-30PA†•• 2000-60PA†•• 2000-100PA†• 2000-125PA†• 2000-250PA 2000-300PA 2000-500PA 2000-750PA 2000-1000PA 10-0-50 0-30 0-60 0-100 0-125 0-250 0-300 0-500 0-750 0-1000 Dual Scale English/Metric Models 2300-4CM 2300-10CM 2300-30CM 2-0-2 5-0-5 15-0-15 Model Range, in w.c. Range, Pa or kPa Zero Center Ranges 2000-00D†•• 2000-0D†• 2001D 2002D 2003D 2004D 2005D 2006D 2008D 2010D 2015D 2020D 2025D 2050D 2060D 0-.25 0-0.5 0-1.0 0-2.0 0-3.0 0-4.0 0-5.0 0-6.0 0-8.0 0-10 0-15 0-20 0-25 0-50 0-60 0-62 Pa 0-125 Pa 0-250 Pa 0-500 Pa 0-750 Pa 0-1.0 kPa 0-1.25 kPa 0-1.5 kPa 0-2.0 kPa 0-2.5 kPa 0-3.7 kPa 0-5 kPa 0-6.2 kPa 0-12.4 kPa 0-15 kPa 2300-00†•• 2300-0†• 2301 2302 2304 2310 2320 2330 0.125-0-0.125 .25-0-.25 .5-0-.5 1-0-1 2-0-2 5-0-5 10-0-10 15-0-15 Zero Center Ranges Model Range, Pa 2300-60PA†•• 2300-100PA†• 2300-120PA 2300-200PA 2300-250PA 2300-300PA 2300-500PA 2300-1000PA 30-0-30 50-0-50 60-0-60 100-0-100 125-0-125 150-0-150 250-0-250 500-0-500 †These ranges calibrated for vertical scale position. • Accuracy ±3%. •• Accuracy ±4%. *MP option standard. **HP option standard. USA: California Proposition 65 WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. YEAR LIMITED WARRANTY |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |