13 / 20 page ![]() Enclosed automatic transfer switches General & technical specification Specific ratings according to IEC 60947-3 40A to 125A Rated free air thermal current (Ith) and operational current in AC20 at 40°C ambient temperature A 40 63 80 115 125 Rated enclosed thermal current (Ith) and operational current in AC20 at 40°C ambient temperature A 40 63 80 115 125 Rated operational current AC 21A and AC 22A at voltages up to 500V A 40 63 80 100 125 Rated operational current AC23A at voltages up to 415V A 40 63 80 80 90 Rated AC 23 breaking capacity at 415V A 320 504 640 640 720 Rated conditional short circuit current Ip (r.m.s.) at 415V, 50kA net kA 16.5 16.5 16.5 16.5 16.5 and corresponding max. allowed cut-off current of gG A 125 125 125 125 125 Rated short time withstand current Icw 690v (1sec), (r.m.s. value) kA 2.5 2.5 2.5 2.5 2.5 Rated short time making capacity Icm, peak value 690v kA 3.6 3.6 3.6 3.6 3.6 Mechanical endurance / switch Oper 20000 20000 20000 20000 20000 Rated short-time withstand current Icw (r.m.s.) 690V, 0,1 sec kA 5 5 5 5 5 Rated operational current, AC-31B, up to 415V A 40 63 80 100 125 Rated operational current, AC-33B, up to 415V A 40 63 80 80 80 The handle is a direct mounted type, and it shall be padlockable in the “0” position with three padlocks with 5 …6 mm. It is possible to operate switch with the manual handle in case of emergency, regardless of the position of switch and without any supply power. Technical specifications according to IEC 60947-3 and IEC 60947-6-1 • Type of equipment ATSE • Class of equipment PC • Rated operational voltage, Ue Max. 415 V • Rated impulse withstand voltage, Uimp 6 kV • Rated frequency 50 - 60 Hz • EMC environment A and B Bypass Requirement In order to comply with BS8519 which states “Where the availability of the life safety and fire-fighting equipment is conditional to the occupation of the building, a bypass arrangement should be incorporated to enable the changeover device to be maintained without loss of service from the critical plant”. The bypass switches consist of the following; Single or mains bypass A closed transition manual changeover switch is included to allow for the seamless (no 0 position giving no break in supply when moving to bypass) transition to bypass. The front of the panel should indicate that the ATS has been bypassed and is safe to carry out maintenance. Dual Bypass A closed transition manual changeover switch is included to allow for the seamless (no 0 position giving no break in supply when moving to bypass) transition to bypass. Together with a standard manual changeover switch to allow you to choose between supply 1 or supply 2. The front of the panel should indicate that the ATS has been bypassed and which supply is feeding the load and is safe to carry out maintenance. Specific ratings according to IEC 60947-3 160A to 1600A Rated free air thermal current (Ith) and operational current in AC20 at 40°C ambient temperature A 160 200 250 315 400 630 800 1000 1250 1600 Rated enclosed thermal current (Ith) and operational current in AC20 at 40°C ambient temperature A 160 200 250 315 400 630 800 1000 120 1600 Rated operational current AC 21A and AC 22A at voltages up to 415V A 160 200 250 315 400 630 800 1000 1250 1600 Rated operational current AC23A at voltages up to 415V A 160 200 250 315 400 630 800 1000 1250 1250 Rated AC 23 breaking capacity at 415V A 1280 1600 2000 2520 3200 5040 6400 10000 10000 10000 Rated conditional short circuit current Ip (r.m.s.) at 415V, 50kA net kA 40.5 40.5 40.5 59 59 83.5 83.5 100 100 100 and corresponding max. allowed cut-off current of gG A 355 355 355 500 500 800 800 1250 1250 1250 Rated short time withstand current Icw 690v (1sec), (r.m.s. value) kA 8 8 8 15 15 20 20 50 50 50 Rated short time making capacity Icm, peak value 690v kA 30 30 30 65 65 80 80 92 92 92 Mechanical endurance / switch Oper 16000 16000 16000 16000 16000 10000 10000 6000 6000 6000 Rated short-time withstand current Icw (r.m.s.) 690V, 0,1 sec kA 15 15 15 25 25 38 38 50 50 50 Rated operational current, AC-31B, up to 415V A 160 200 250 315 400 650 720 1000 1250 1600 Rated operational current, AC-33B, up to 415V A 160 200 250 315 400 650 650 1000 1000 1000 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |