  DIO59078CL16 Datasheet HTML 1Page - DIOO MICROCIRCUITS CO., LTD DIO59078CL16 Datasheet HTML 2Page - DIOO MICROCIRCUITS CO., LTD DIO59078CL16 Datasheet HTML 3Page - DIOO MICROCIRCUITS CO., LTD DIO59078CL16 Datasheet HTML 4Page - DIOO MICROCIRCUITS CO., LTD DIO59078CL16 Datasheet HTML 5Page - DIOO MICROCIRCUITS CO., LTD DIO59078CL16 Datasheet HTML 6Page - DIOO MICROCIRCUITS CO., LTD DIO59078CL16 Datasheet HTML 7Page - DIOO MICROCIRCUITS CO., LTD DIO59078CL16 Datasheet HTML 8Page - DIOO MICROCIRCUITS CO., LTD DIO59078CL16 Datasheet HTML 9Page - DIOO MICROCIRCUITS CO., LTD Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 17 page
background image
DIO5907x
www.dioo.com
© 2026 Dioo Microcircuits Co., Ltd. Jiangsu
DIO5907x• Rev.1.6
- 5 -
TMR
I
Timer Programming Input. TMR controls the pre-charge and fast-charge safety timers.
Connect TMR to VSS to disable all safety timers. Connect a 18 kΩ to 72 kΩ resistor
between TMR and VSS to program the timers a desired length. Leave TMR
unconnected to set the timers to the default values.
TD
I
Termination Disable Input. Connect TD high to disable charger termination. Connect TD
to VSS to enable charger termination. TD is internally pulled down to VSS with
approximately 270 kΩ. Do not leave TD unconnected to ensure proper operation.
(DIO59073/73B).
ITERM
I
Termination Current Programming Input. Connect a resistor from ITERM to VSS to
program the termination current. (DIO59078 only).
SYSOFF
I
System Enable Input. Connect SYSOFF high to turn off the FET connecting the battery
to the system output. When an adapter is connected, charging is also disabled. Connect
SYSOFF low for normal operation. SYSOFF is internally pulled up to VBAT through a
large resistor (approximately 7 MΩ). Do not leave SYSOFF unconnected to ensure
proper operation. (DIO59075/76).
ISET
I/O
Fast Charge Current Programming Input. Connect a 590 Ω to 8.9 kΩ resistor from ISET
to VSS to program the fast charge current level. Charging is disabled if ISET is left
unconnected. While charging, the voltage at ISET reflects the actual charging current
and can be used to monitor charge current.
EP
-
Not internally connect to GND. Recommend to connect to a large ground plane for
improved thermal performance.
Table 1. EN1 / EN2 Settings
EN2
EN1
Maximum Input Current Into IN Pin
0
0
100 mA. USB100 mode
0
1
500 mA. USB500 mode
1
0
Set by an external resistor from ILIM to VSS
1
1
Standby (USB suspend mode)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com