17 / 31 page  17 sensing.honeywell.com MICRO SWITCH™ General Purpose Limit Switches O.T. • Operating torque O.F. • Operating force R.P. • Release point P.T. • Pretravel O.T. • Overtravel D.T. • Differential travel Table 16. Side Rotary, Adjustable Rod Lever Compact 20 mm conduit Compact PG 13,5 conduit Plug-in less base* Description Electrical Rating (Table 2) Operating Torque or Force Bar Chart1 Operate Point Pretravel (max.) Overtravel (min.) Differen- tial Travel (max.) Notes 1LS10-4C 1LS10-4PG 201LS10-4 Side rotary with 140 mm [5.5 in] max. adjustable aluminum rod J 0,51 N m [4.5 in-lb] TT 1-2 3-4 0° 20° 50° 3-4 1-2 OP FP DT = 12° 8° – 20° 30° 12° 1LS47-4PG – – Side rotary with 140 mm [5.5 in] max. adjustable alumnum rod J 0,51 N m [4.5 in-lb] TT 1-2 3-4 0° 5° 35° 3-4 1-2 OP FP DT = 4° 1° – 5° 30° 4° Low pretravel 1 Contact closed n; Contact open o. * Requires an 18PA1-4C Terminal Block (20 mm conduit threads) or 18PA1-4PG Terminal Block (PG13,5 conduit threads) ordered separately. Terminal block is base receptacle. Table 17. Top Pin Plunger Compact 20 mm conduit Compact PG 13,5 conduit Plug-in less base* Description Electrical Rating (Table 2) Operating Torque or Force Bar Chart1 Free Position (nom.) Operate Point Pretravel (max.) Overtravel (min.) Differen- tial Travel (max.) Notes 2LS1-4C 2LS1-4PG 202LS1-4 Top pin plunger (SST) J 31,4 N [7.06 lb] TT 1-2 3-4 35,5 33,8 27,43 3-4 1-2 OP FP DT = 0,50 34,29 35,5 mm [1.40 in] 33,8 mm ±0,7 mm [1.33 in ±0.03 in] 1,70 mm [0.067 in] 6,40 mm [0.252 in] 0,50 mm [0.02 in] – 2LS1-4GPG – Top pin plunger (SST) F 31,4 N [7.06 lb] 35,5 mm [1.40 in] 33,8 mm ±0,7 mm [1.33 in ±0.03 in] 1,70 mm [0.067 in] 6,40 mm [0.252 in] 0,50 mm [0.02 in] Gold-plated contacts, low-energy loads 2LS1-4CN151 – – Top pin plunger (SST) J 31,4 N [7.06 lb] 35,5 mm [1.40 in] 33,8 mm ±0,7 mm [1.33 in ±0.03 in] 1,70 mm [0.067 in] 6,40 mm [0.252 in] 0,50 mm [0.02 in High temperature, 150 °C [302 °F] 1 Contact closed n; Contact open o. NOTE: Bar chart measurements are in millimeters. * Requires an 18PA1-4C Terminal Block (20 mm conduit threads) or 18PA1-4PG Terminal Block (PG13,5 conduit threads) ordered separately. Terminal block is base receptacle. Table 18. Top Roller Plunger Compact 20 mm conduit Compact PG 13,5 conduit Plug-in less base* Description Electrical Rating (Table 2) Operating Torque or Force Bar Chart1 Free Position (nom.) Operate Point Pretravel (max.) Overtravel (min.) Differen- tial Travel (max.) Notes 5LS1-4C 5LS1-4PG 205LS1-4 Top roller plunger (SST) J 31,4 N [7.06 lb] TT 1-2 3-4 45,7 44,0 38,35 3-4 1-2 OP FP DT = 0,51 44,46 45,7 mm [1.80 in] 44,0 mm ±0,7 mm [1.73 in ±0.03 in] 1,70 mm [0.067 in] 5,56 mm [0.219 in] 0,50 mm [0.02 in] – 5LS1-G- 4PG – Top roller plunger (SST) F 31,4 N [7.06 lb] 45,7 mm [1.80 in] 44,0 mm ±0,7 mm [1.73 in ±0.03 in] 1,70 mm [0.067 in] 5,56 mm [0.219 in] 0,50 mm [0.02 in] Gold-plated contacts, low-energy loads 5LS1-4CN152 – – Top roller plunger (SST) J 31,4 N [7.06 lb] 45,7 mm [1.80 in] 44,0 mm ±0,7 mm [1.73 in ±0.03 in] 1,70 mm [0.067 in] 5,56 mm [0.219 in] 0,50 mm [0.02 in] High temperature, 150 °C [302 °F] 1 Contact closed n; Contact open o. NOTE: Bar chart measurements are in millimeters. * Requires an 18PA1-4C Terminal Block (20 mm conduit threads) or 18PA1-4PG Terminal Block (PG13,5 conduit threads) ordered separately. Terminal block is base receptacle. |
|