| Electronic Components Datasheet Search |
|
MPX2100AP Datasheet(PDF) 2 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPX2100AP Datasheet(HTML) 2 Page - Freescale Semiconductor, Inc |
|
2 / 10 page ![]() MPX2100 Sensors 2 Freescale Semiconductor Pressure Figure 1 shows a block diagram of the internal circuitry on the stand-alone pressure sensor chip. Figure 1. Temperature Compensated Pressure Sensor Schematic Voltage Output versus Applied Differential Pressure The differential voltage output of the sensor is directly proportional to the differential pressure applied. The absolute sensor has a built-in reference vacuum. The output voltage will decrease as vacuum, relative to ambient, is drawn on the pressure (P1) side. The output voltage of the differential or gauge sensor increases with increasing pressure applied to the pressure side (P1) relative to the vacuum side (P2). Similarly, output voltage increases as increasing vacuum is applied to the vacuum side (P2) relative to the pressure side (P1). VS 3 Sensing Element Thin Film Temperature Compensation and Calibration Circuitry 2 4 +VOUT -VOUT 1 GND |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|