2 / 8 page ![]() INSTALLATION TYPICAL INSTALLATIONS AND WIRING DIAGRAMS Figure 3 PIPING Figure 3 shows a typical piping schematic of Magnetrol J52 level switches installed on a liquid accumulator. Appropriate reference mark on control float chamber should be aligned to correspond with liquid level at which switch control is desired (switch operates at upper mark on increasing level and lower mark at decreasing level). Use pipe of sufficient strength to support the control. All piping should be straight and free of “low spots” or “pock- ets” so that the lower liquid line will drain towards the liquid accumulator (or receiver), and upper vapor line will drain toward the control. Shut-off valves are recommended for installation between accumulator (or receiver), and control float chamber. If control is to be used with a low temperature liquid (one which will “boil” in float chamber if outside heat is absorbed), the chamber and piping should be insulated. Such boiling in the chamber will cause false level indica- tions. Do NOT insulate switch mechanism housing. MOUNTING Adjust piping as required to bring control to a vertical posi- tion. Magnetrol controls must be mounted within three (3°) degrees of the vertical. A three-degree slant is noticeable by eye, but installation should be checked with a spirit level on top or sides of float chamber. WIRING The standard Model J52 with NEMA 4 housing is furnished with 24" (610 mm) long lead wires for ease in connection at a close junction box. Wires are sealed in a conduit outlet adaptor fitting, color coded and numbered to allow control wiring without the need to remove the sealed housing cover. All switch electrical ratings are stamped on the hous- ing cover nameplate. If desired, conduit outlet may be repo- sitioned for wiring convenience by loosening set screw(s) located under the housing base; however, housing cover must be removed and switch mechanism locking screw loosened so that mechanism can be rotated together with housing base. NOTE: Before placing control into service, be certain cover gasketed joints are tight to prevent infiltration of moisture laden air or corrosive gases to the switch mechanism. CAUTION: Level controls are shipped from the factory with the enclosing tube tightened and the middle set screw, on the housing base, locked to the enclosing tube. Failure to loosen the set screw prior to repositioning the conduit con- nection may cause the enclosing tube to loosen, resulting in the possible leakage of the process liquid or vapor. 4 High Level Alarm terminals Pump On terminals Pump Off terminals Line Starter with 3-wire pilot circuit 5 6 4 5 6 4 5 6 Pump Motor Coil Line Alarm Pump Off Pump On Chamber mark indicates actuating levels High Level Alarm SUCTION TO COMPRESSOR LIQUID ACCUMULATOR MODEL J52 MAGNETROL CONTROLS INSTALLATION SHOWING PUMP CONTROL AND HIGH LEVEL ALARM SUCTION FROM COOLERS TO PUMP 2 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |