Electronic Components Datasheet Search
  British  ▼
ALLDATASHEET.CO.UK

X  

H2PROT Datasheet(PDF) 4 Page - rfsolutions.ltd

Part # H2PROT
Description  Typical application configuration for Micro RWD module
PDF  9 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  RFSOLUTIONS [rfsolutions.ltd]
Direct Link  http://www.rfsolutions.co.uk
Logo RFSOLUTIONS - rfsolutions.ltd

H2PROT Datasheet(HTML) 4 Page - rfsolutions.ltd

  H2PROT Datasheet HTML 1Page - rfsolutions.ltd H2PROT Datasheet HTML 2Page - rfsolutions.ltd H2PROT Datasheet HTML 3Page - rfsolutions.ltd H2PROT Datasheet HTML 4Page - rfsolutions.ltd H2PROT Datasheet HTML 5Page - rfsolutions.ltd H2PROT Datasheet HTML 6Page - rfsolutions.ltd H2PROT Datasheet HTML 7Page - rfsolutions.ltd H2PROT Datasheet HTML 8Page - rfsolutions.ltd H2PROT Datasheet HTML 9Page - rfsolutions.ltd  
Zoom Inzoom in Zoom Outzoom out
 4 / 9 page
background image
ib technology
4
Command Protocol
The following commands are supported. The corresponding acknowledge code should
be read back by the host and decoded to confirm that the command was received and
actioned correctly. The serial bit protocol is 9600 baud, 8 bits, 1 stop, no parity (lsb
transmitted first).
The status flags returned in the Acknowledge byte are as follows:
b7 b6 b5 b4 b3 b2 b1 b0
1
1
1
1
1 1 1 1
|
|
|
|
|
EEPROM error (Internal EEPROM write error)
|
|
|
| Tag OK (Tag identity code matched to list and Password exchange successful)
|
|
| Rx OK (Tag communications and acknowledgement OK)
|
|
RS232 error (Host serial communications error)
|
RELAY Enabled flag
HTRC (or Antenna fault) error flag
Note that bits 6 and 7 are fixed 1’s so that an acknowledge code of D6 (Hex) would
generally indicate no errors with a matched (or authorised) HT2 Tag present.
Note also that only the relevant flags are set after each command as indicated in the
following specification.
Write Tag
Command to write 4 bytes of data to HT2 32 bit page. If the write was unsuccessful
(invalid tag or out of field) then Status flags in acknowledge byte indicate error.
B7
B0
Command:
0 1 0 1 0 1 1 1
(ASCII “W”, 0x57)
Argument1:
x x x x x N N N
(N = HT2 page address 0-7)
Argument2:
D D D D D D D D
(D = msb data to write to HT2)
Argument3:
D D D D D D D D
Argument4:
D D D D D D D D
Argument5:
D D D D D D D D
(D = lsb data to write to HT2)
Acknowledge:
1 1 F F F F F X
(F = Status flags)
Note that PASSWORD exchange occurs for WRITE command.
If no tag present then acknowledge / status byte reply is 0xC0
If tag present but RWD PASSWORD check fails then acknowledge byte reply is 0xC0.
If tag present but TAG PASSWORD check fails then acknowledge byte reply is 0xC4.
If tag present and both PASSWORDS match then acknowledge reply is 0xD6.



Html Pages

1 2 3 4 5 6 7 8 9


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com