15 / 20 page ![]() REV. 0 ADF4106 –15– Fastlock Mode 2 The charge pump current is switched to the contents of Current Setting 2. The device enters Fastlock by having a “1” written to the CP Gain bit in the AB counter latch. The device exits Fastlock under the control of the Timer Counter. After the timeout period determined by the value in TC4–TC1, the CP Gain bit in the AB counter latch is automatically reset to “0” and the device reverts to normal mode instead of Fastlock. See Table V for the timeout periods. Timer Counter Control The user has the option of programming two charge pump cur- rents. The intent is that the Current Setting 1 is used when the RF output is stable and the system is in a static state. Current Setting 2 is meant to be used when the system is dynamic and in a state of change (i.e., when a new output frequency is programmed). The normal sequence of events is as follows: Users initially decide what the preferred charge pump currents are will be. For example, they may choose 2.5 mA as Current Setting 1 and 5 mA as the Current Setting 2. At the same time they must also decide how long they want the secondary cur- rent to stay active before reverting to the primary current. This is controlled by the Timer Counter Control Bits DB14 to DB11 (TC4–TC1) in the Function Latch. The truth table is given in Table V. Now, when users wish to program a new output frequency, they can simply program the AB counter latch with new values for A and B. At the same time they can set the CP Gain bit to a “1,” which sets the charge pump with the value in CPI6–CPI4 for a period of time determined by TC4–TC1. When this time is up, the charge pump current reverts to the value set by CPI3–CPI1. At the same time the CP Gain bit in the A, B Counter latch is reset to 0 and is now ready for the next time that the user wishes to change the frequency again. Note that there is an enable feature on the Timer Counter. It is enabled when Fastlock Mode 2 is chosen by setting the Fastlock Mode bit (DB10) in the Function Latch to “1.” Charge Pump Currents CPI3, CPI2, CPI1 program Current Setting 1 for the charge pump. CPI6, CPI5, CPI4 program Current Setting 2 for the charge pump. The truth table is given in Table V. Prescaler Value P2 and P1 in the Function Latch set the prescaler values. The prescaler value should be chosen so that the prescaler output frequency is always less than or equal to 300 MHz. Thus, with an RF frequency of 4 GHz, a prescaler value of 16/17 is valid but a value of 8/9 is not valid. PD Polarity This bit sets the Phase Detector Polarity Bit. See Table V. CP Three-State This bit controls the CP output pin. With the bit set high, the CP output is put into three-state. With the bit set low, the CP output is enabled. THE FUNCTION LATCH With C2, C1 set to 1,0, the on-chip function latch will be programmed. Table V shows the input data format for program- ming the Function Latch. Counter Reset DB2 (F1) is the counter reset bit. When this is “1,” the R counter and the A,B counters are reset. For normal operation this bit should be “0.” Upon powering up, the F1 bit needs to be disabled (set to “0”). The N counter then resumes counting in “close” align- ment with the R counter. (The maximum error is one prescaler cycle). Power-Down DB3 (PD1) and DB21 (PD2) on the ADF4110 Family, provide programmable power-down modes. They are enabled by the CE pin. When the CE pin is low, the device is immediately disabled regardless of the states of PD2, PD1. In the programmed asyn- chronous power-down, the device powers down immediately after latching a “1” into bit PD1, with the condition that PD2 has been loaded with a “0.” In the programmed synchronous power-down, the device power down is gated by the charge pump to prevent unwanted frequency jumps. Once the power- down is enabled by writing a “1” into bit PD1 (on condition that a “1” has also been loaded to PD2), then the device will go into power-down on the occurrence of the next charge pump event. When a power down is activated (either synchronous or asynchronous mode including CE-pin-activated power down), the following events occur: All active dc current paths are removed. The R, N, and timeout counters are forced to their load state conditions. The charge pump is forced into three-state mode. The digital clock detect circuitry is reset. The RFIN input is debiased. The reference input buffer circuitry is disabled. The input register remains active and capable of loading and latching data. MUXOUT Control The on-chip multiplexer is controlled by M3, M2, M1 on the ADF4110 Family. Table V shows the truth table. Fastlock Enable Bit DB9 of the Function Latch is the Fastlock Enable Bit. Only when this is “1” is Fastlock enabled. Fastlock Mode Bit DB10 of the Function Latch is the Fastlock Mode bit. When Fastlock is enabled, this bit determines which Fastlock Mode is used. If the Fastlock Mode bit is “0,” Fastlock Mode 1 is selected and if the Fastlock Mode bit is “1,” Fastlock Mode 2 is selected. Fastlock Mode 1 The charge pump current is switched to the contents of Current Setting 2. The device enters Fastlock by having a “1” written to the CP Gain bit in the AB counter latch. The device exits Fastlock by having a “0” written to the CP Gain bit in the AB counter latch. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |