Back Button VN800PSTR-E Datasheet HTML 5Page - STMicroelectronics VN800PSTR-E Datasheet HTML 6Page - STMicroelectronics VN800PSTR-E Datasheet HTML 7Page - STMicroelectronics VN800PSTR-E Datasheet HTML 8Page - STMicroelectronics VN800PSTR-E Datasheet HTML 9Page - STMicroelectronics VN800PSTR-E Datasheet HTML 10Page - STMicroelectronics VN800PSTR-E Datasheet HTML 11Page - STMicroelectronics VN800PSTR-E Datasheet HTML 12Page - STMicroelectronics VN800PSTR-E Datasheet HTML 13Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 27 page
background image
VN800PS-E
Electrical specifications
Doc ID 15610 Rev 3
9/27
IINH
High level input current
VIN=3.25 V
-
10
µA
VI(hyst)
Input hysteresis voltage
0.5
-
V
IIN
Input current
VIN =VCC = 36 V
-
200
µA
Table 7.
Input pin (continued)
Symbol
Parameter
Test conditions
Min.
Typ.
Max.
Unit
Table 8.
VCC - output diode
Symbol
Parameter
Test conditions
Min.
Typ.
Max.
Unit
VF
Forward on voltage
-IOUT = 0.6 A; Tj = 150 °C
-
-
0.6
V
Table 9.
Status pin
Symbol
Parameter
Test conditions
Min.
Typ.
Max.
Unit
VSTAT
Status low output voltage ISTAT =1.6 mA
-
-
0.5
V
ILSTAT
Status leakage current
Normal operation; VSTAT =VCC =36V
-
-
10
µA
CSTAT
Status pin input
capacitance
Normal operation; VSTAT =5V
-
-
30
pF
Table 10.
Protections(1)
Symbol
Parameter
Test conditions
Min.
Typ.
Max.
Unit
TTSD
Shutdown temperature
150
175
200
°C
TR
Reset temperature
135
°C
Thyst
Thermal hysteresis
7
15
°C
TSDL
Status delay in overload
condition
Tj>Tjsh
20
µs
Ilim
DC short circuit current
VCC =24V; RLOAD =10mΩ
0.7
2
A
Vdemag
Turn-off output clamp voltage
IOUT = 0.5 A; L=6mH
VCC -47 VCC -52 VCC -57
V
1.
To ensure long term reliability under heavy overload or short circuit conditions, protection and related diagnostic signals
must be used together with a proper software strategy. If the device is subjected to abnormal conditions, this software must
limit the duration and number of activation cycles.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com