| Electronic Components Datasheet Search |
|
CMPWR160SA Datasheet(PDF) 6 Page - California Micro Devices Corp |
|
|
|||||||||||||||||||||||||||||
CMPWR160SA Datasheet(HTML) 6 Page - California Micro Devices Corp |
|
6 / 10 page ![]() CALIFORNIA MICRO DEVICES ©2000 California Micro Devices Corp. All rights reserved. SmartOR™ is a trademark of California Micro Devices Corporation. 12/5/2000 215 Topaz Street, Milpitas, California 95035 Tel: (408) 263-3214 Fax: (408) 263-7846 www.calmicro.com 6 CMPWR160 Typical Transient Characteristics The transient characterization test setup is shown in Figure 6. It was the setup used for the transient tests unless specified otherwise. A maximum rated load current of 6.6 Ω (500mA @ 3.3V) was used during characterization along with a nominal V CC supply voltage of 5V DC, unless specified otherwise. The load transient characterization was done by switch- ing between 6.6 and 660 Ω load resistors. This switched the load between 500 and 5mA respectively. For the V CC power-up and power-down characterizations V CC supply was ramped between 0 and 5V. Both the rise and fall times for the V CC power-up/down pulses were controlled to be 15ms. In the line transient characterizations the V CC supply voltage was controlled to step between 4.5 to 5.5V. For the POR response characterization V CC and SD were tied to ground and the V OUT voltage was directly driven between 2.7 and 3.1V. This was done by connecting a function generator directly to the output of the device. These voltage values were picked because it drove V OUT directly across the typical POR threshold voltage of 2.9V. V CC was tied to ground to show that the POR circuitry will operate even when the V CC supply voltage is not present. The oscilloscope traces show the full bandwidth re- sponse at the SD, POR, V CC and VOUT pins depending on the characterization. VCC VOUT GND C1 10µF C2 0.1µF + C3 0.1µF C4 10µF (500mA) 6.6 Ω + GND VCC SD GND POR VOUT CMPWR160 POR Figure 6. Transient Characterization Test Setup V CC power-up Cold Start Figure 7 shows the output response during an initial V CC power up with SD tied to V CC. When VCC reaches a particular threshold, the regulator turns on. The un- charged output capacitor causes maximum inrush current to flow. At this point the device sees the output as a short circuit and the device enters a protective current limiting mode. The output capacitor quickly charges and V OUT rises. Once this voltage rises to just below V CC the inrush current stops flowing and the output rises with the input. V OUT continues to rise with the input until it reaches 3.3V. Figure 7. V CC Power-up Cold Start 280mV (500mA Load) VCC VOUT M 2.00ms 1.00V Ch2 1.00V 25.0kS/s Tek Run Sample Ch2 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |