| Electronic Components Datasheet Search |
|
KX750 Datasheet(PDF) 2 Page - C&D Technologies |
|
|
|||||||||||||||||||||||||||||
KX750 Datasheet(HTML) 2 Page - C&D Technologies |
|
2 / 4 page ![]() KX750 4/99 REV B Page 2 Remote Sense Remote Sense is provided on all outputs and will compensate for 0.7V of line drop. Remote Sense leads are protected against open, short, and reversal. Remote On/Off The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Consult the factory for other options. Over Voltage Protection Output #1: 6.25V, ±0.8 VDC. The power supply will latch off until AC power is cycled. Over Current Protection Individual current limit on all outputs. Automatic recovery upon fault removal. Reverse Voltage Protection All outputs are protected to rated load. Transient Response The peak output voltage excursion on the main output will not exceed 2% and will recover within 1% in 200 µSec for a 25% load step change. Output Isolation All outputs are fully isolated. Power Fail Signal Upon AC input voltage removal, the power fail signal drops to logic zero at least 5msec before loss of DC output. Upon AC input turn-on, signal remains low until outputs are in regulation referenced to (-) sense terminal. Consult the factory for other options. DC Power Good Signal Upon a ±10% loss of regulation on any output, the DC Good signal drops to a logic zero referenced to (-) sense terminal. Consult the factory for other options. Over Temperature Protection Internal thermal switch turns off power supply if overheating occurs and automatically restarts when temperature drops below threshold. Safety UL Recognized: UL File Number 14675 (1950 & 1012) CSA Certified: CSA File Number LR9070-154C (C22.2 No. 234-M90, Level 6) TUV License Number:R9576032 (EN60950) (IEC950) Cooling The unit is designed to operate with 30 CFM of airflow. Input Specifications Parameter Conditions Min Typ Max Units Operating Range 47-63Hz 90 264 VAC Inrush Current 120VAC, cold start 40 APK 240VAC, cold start 80 APK Efficiency Nominal line and full load 75 % Power Factor Correction (PFC) Meets EN61000-3-2 0.99 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |