MAS281 Datasheet(PDF) 9 Page - Dynex Semiconductor |
|
|
|||||||||||||||||||||||||||||
MAS281 Datasheet(HTML) 9 Page - Dynex Semiconductor |
|
9 / 55 page ![]() MAS281 9/55 2.2.23 TRIGGER-GO CLOCK (TGCLK) This clock input is used by the internal 16-bit trigger-go counter. The trigger-go counter counts at the same frequency as TGCLK. 2.2.24 TRIGGER-GO DISCRETE (TGO) This active low output goes low whenever the trigger-go counter overflows, i e., the counter rolls over to 0000. It returns to the high state when the trigger-go counter is reset by software via the GO XIO command. 2.2.25 DISABLE TIMER (DTIMER) A low on this active low input disables timers A and B as well as the trigger-go counter. A low also disables DMA access by forcing DMAE low and DMAKN high. Raising DTIMERN allows timers A and B and the trigger-go counter to resume counting from the value at which they were stopped. A high also allows normal DMA operation. 2.2.26 DISABLE TIMEOUT (DTO) A low on this active low input will reset and disable the bus fault timeout circuitry. 2.2.27 POWER DOWN INTERRUPT (PWRD) A low on this active low input is captured in the Pl register by a SYNCN high-to-low transition. This sets pending interrupt 0. This is the highest priority interrupt and cannot be masked or disabled. 2.2.28 USER INTERRUPTS (INT02,08,10,11,13 AND 15) A low on any of these active low inputs will be captured in the Pl register by a SYNCN high-to-low transition and will set pending interrupt levels 2, 8, 10, 11, 13, and 15, respectively. Level 2 is the highest priority user level while level 15 is the lowest priority. These interrupts are maskable and can be disabled. Unused inputs should be pulled up to VDD. [NOTE: The INTO2 service routine should clear the PI Register using the RPI 0002 instruction.] 2.2.29 I/0 DEDICATED INTERRUPTS (IOI1 & IOI2) A low on either IOI1N or IOI2N will be captured in the Pl register by a SYNCN high-to-low transition and will set pending interrupt levels 12 and 14, respectively. Unused inputs should be pulled up to VDD. [NOTE: Interrupt levels 1, 3, 4, 5, 6, 7, and 9 are dedicated to internal machine interrupts.] 2.2.30 MEMORY PROTECT ERROR (MPROE) A low on this active low input, captured by the SYNCN high-to-low transition, is used to inform the module that an access fault, execute protect, or write protect violation has been detected. Bit O of the module Fault Register (FT) is set if this signal goes low during a memory cycle; bit 1 is set if it goes low during a DMA cycle. Either condition immediately sets pending interrupt level 1 and in the case of a memory cycle error, causes the currently executing MIL-STD-1750A instruction to be aborted. Although the MAS281 aborts the macroinstruction, system memory management, and / or block protect hardware is responsible for preventing the erroneous bus cycle from accessing memory. To effectively use this feature, MPROEN should be pulled low prior to the high-to-low SYNCN transition of the next machine cycle. This can easily be accomplished by injecting wait states to hold off the DSN rising edge (write cycle) and the SYNCN falling edge (read cycle) until the system protection circuitry can decide whether or not to allow the transaction. 2.2.31 MEMORY PARITY ERROR (MPE) A low on this active low input, captured by the SYNCN high-to-low transition, is used to inform the module that a parity error has been detected during a memory transfer. Bit 2 of the module Fault Register (FT) is set when this signal goes low. This, in turn, causes pending interrupt level 1 to be set. 2.2.32 PROGRAMMED I/O PARITY ERROR (PIOPE) A low on this active low input, captured by the SYNCN high-to-low transition, is used to inform the module that a parity error has been detected during an external l/O transfer. Bit 3 of the module Fault Register (FT) is set when this signal goes low. This, in turn, causes pending interrupt level 1 to be set. 2.2.33 DMA PARITY ERROR (DMAPE) A low on this active low input, captured by the SYNCN high-to-low transition, is used to inform the module that a parity error has been detected during a DMA data transfer. Bit 4 of the module Fault Register (FT) is set when this signal goes low This, in turn, causes pending interrupt level 1 to be set. 2.2.34 EXTERNAL ADDRESS ERROR (EXADE) A low on this active low input, captured by the SYNCN high-to-low transition, is used to inform the module that a system address error has been detected. Bit 8 of the module Fault Register (FT) is set when this signal goes low during a Bit Device 15 Console 14 MMU 13 BPU 12 Output Discrete Register 11-0 Unused Table 1: Configuration Register Bit Assignment |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |