11 / 20 page ![]() 11 Figure 1. VOH vs. Temperature. Notes: 1. Derate linearly above 70° C free-air temperature at a rate of 0.3 mA/°C. 2. Maximum pulse width = 10 µs, maximum duty cycle = 0.2%. This value is intended to allow for component tolerances for designs with IO peak minimum = 2.0 A. See Applications section for additional details on limiting IOH peak. 3. Derate linearly above 70° C free-air temperature at a rate of 4.8 mW/°C. 4. Derate linearly above 70° C free-air temperature at a rate of 5.4 mW/°C. The maximum LED junction temperature should not exceed 125°C. 5. Maximum pulse width = 50 µs, maximum duty cycle = 0.5%. 6. In this test VOH is measured with a dc load current. When driving capacitive loads VOH will approach VCC as IOH approaches zero amps. 7. Maximum pulse width = 1 ms, maximum duty cycle = 20%. 8. In accordance with UL1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 4500 Vrms for 1 second (leakage detection current limit, II-O ≤ 5 µA). 9. In accordance with UL1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 4500 Vrms for 1 second (leakage detection current limit, II-O ≤ 5 µA). 10. In accordance with UL1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 6000 Vrms for 1 second (leakage detection current limit, II-O ≤ 5 µA). 11. Device considered a two-terminal device: pins 1, 2, 3, and 4 shorted together and pins 5, 6, 7, and 8 shorted together. 12. The difference between tPHL and tPLH between any two ACPL-3130, ACPL-J313 or ACNW3130 parts under the same test condition. 13. Pins 1 and 4 need to be connected to LED common. 14. Common mode transient immunity in the high state is the maximum tolerable dVCM/dt of the common mode pulse, VCM, to assure that the output will remain in the high state (i.e., VO > 15.0 V). 15. Common mode transient immunity in a low state is the maximum tolerable dVCM/dt of the common mode pulse, VCM, to assure that the output will remain in a low state (i.e., VO < 1.0 V). 16. This load condition approximates the gate load of a 1200 V/75A IGBT. 17. Pulse Width Distortion (PWD) is defined as |tPHL - tPLH| for any given device. Figure 3. VOH vs. IOH. Figure 2. IOH vs. Temperature. Figure 4. VOL vs. Temperature. Figure 5. IOL vs. Temperature. Figure 6. VOL vs. IOL. -40 -4 TA - TEMPERATURE - °C 100 -1 -2 -20 0 0 2 0 40 -3 60 80 IF = 7 to 16 mA IOUT = -100 mA VCC = 15 to 30 V VEE = 0 V -40 1.0 TA - TEMPERATURE - °C 100 1.8 1.6 -20 2.0 0 2 0 40 1.2 60 80 IF = 7 to 16 mA VOUT = (V CC - 4 V) VCC = 15 to 30 V VEE = 0 V 1.4 0 -6 IOH - OUTPUT HIGH CURRENT - A 2.5 -2 -3 0.5 -1 1.0 1.5 -5 2.0 IF = 7 to 16 mA VCC = 15 to 30 V VEE = 0 V -4 100 °C 25 °C -40 °C -40 0 TA - TEMPERATURE - °C -20 0.25 0 2 0 0.05 100 0.15 0.20 0.10 40 60 80 VF (OFF) = -3.0 TO 0.8 V IOUT = 100 mA VCC = 15 TO 30 V VEE = 0 V -40 0 TA - TEMPERATURE - °C -20 4 0 2 0 1 100 2 3 40 60 80 VF (OFF) = -3.0 TO 0.8 V VOUT = 2.5 V VCC = 15 TO 30 V VEE = 0 V 0 0 IOL - OUTPUT LOW CURRENT - A 2.5 3 0.5 4 1.0 1.5 1 2.0 VF(OFF) = -3.0 to 0.8 V VCC = 15 to 30 V VEE = 0 V 2 100 °C 25 °C -40 °C |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |