  AN4348 Datasheet HTML 1Page - STMicroelectronics AN4348 Datasheet HTML 2Page - STMicroelectronics AN4348 Datasheet HTML 3Page - STMicroelectronics AN4348 Datasheet HTML 4Page - STMicroelectronics AN4348 Datasheet HTML 5Page - STMicroelectronics AN4348 Datasheet HTML 6Page - STMicroelectronics AN4348 Datasheet HTML 7Page - STMicroelectronics AN4348 Datasheet HTML 8Page - STMicroelectronics AN4348 Datasheet HTML 9Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 25 page
background image
AN4348
How does an electrochemical gas sensor work?
DocID025166 Rev 1
3/25
1
How does an electrochemical gas sensor work?
An electrochemical gas sensor (see Figure 2) contains a gas membrane and two or three
electrodes in contact with an electrolyte. The sensor is impermeable to the electrolyte. Gas
enters the sensor through the gas membrane which limits the rate of gas diffusion
(therefore impacting the sensitivity of the sensor). When gas reaches the working electrode
(WE), a chemical reaction occurs: either oxidation (loss of electrons) occurs from the gases
CO, H2S, sulfur dioxide (SO2), and nitrogen monoxide (NO), or reduction (gain of electrons)
occurs from the gases O2, NO2, and chlorine (Cl2). The reaction depends on the sensor.
If oxidation occurs at the WE, the complimentary reaction (reduction) occurs at its counter
electrode (CE).
For example, in the case of a CO sensor (see Figure 2), oxidation occurs at its WE:
CO + H2O → CO2 + 2H
+ + 2e-
At the CE, the reaction is:
½O2 + 2H+ + 2e- → H2O (consumption of oxygen)
Figure 2: Electrochemical gas sensor (CO)
1.
WE = working electrode (often called the "sensing electrode"), CE = counter electrode,
RE = reference electrode (see explanation below)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com