Back Button AN2299 Datasheet HTML 6Page - STMicroelectronics AN2299 Datasheet HTML 7Page - STMicroelectronics AN2299 Datasheet HTML 8Page - STMicroelectronics AN2299 Datasheet HTML 9Page - STMicroelectronics AN2299 Datasheet HTML 10Page - STMicroelectronics AN2299 Datasheet HTML 11Page - STMicroelectronics AN2299 Datasheet HTML 12Page - STMicroelectronics AN2299 Datasheet HTML 13Page - STMicroelectronics AN2299 Datasheet HTML 14Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 10 / 26 page
background image
An innovative STPM01 approach to calibrate the energy meter: fast digital calibration
AN2299
10/26
Rev2
This traditional power calibration procedure for STPM01 based meters is described in detail
in Appendix A.
2.2
Fast Digital calibration procedure: new approach
Energy meters based on STPM01 ASSP device allow a different kind of calibration due to
the following important facts:
●
The device is compound of two independent meter channels for line voltage and
current respectively. Each channel includes its own 8 bits digital calibrator to adjust the
signal amplitude, and digital filter to remove any signal DC component.
●
The device computes RMS values of measured voltage and current, and from such
corrected signals it calculates all different kind of energies (active, reactive, apparent
and active energy of the 1st harmonic) through mathematical modules which are
implemented with hardwired digital structures and therefore, are not objects of
calibration.
●
The device produces an output pulse signal but information can also be read through
Serial Port Interface, SPI, communication channel.
●
The device has an embedded memory, 56 bits, used for configuration and calibration
purposes. The value of these bits can be read or they can be changed temporarily or
permanently through SPI communication channel.
According to what pointed out above, it is possible to calibrate STPM01 based energy
meters by calibration of voltage and current channels rather than of output pulse signal
frequency. Since any energy measure performed by the device (active wide band and active
fundamental, reactive or apparent) is calculated digitally (without error) from current and
voltage calibrated signals, it means that every measure is automatically calibrated if current
and voltage channels are calibrated. Calibration of both channels is performed in such way
to achieve also the target value of power sensitivity constant of meter.
For the calibration procedure described above, it could even be possible to use two
independent line signal generators, because to a certain extent line frequency and phase
between line signals are not of high significance, observing RMS values.
Even more, if the line generator used is precise and stable enough, theoretically, it is
not necessary to have any additional precision energy meter (EMp) to perform the
calibration because only signal amplitudes (voltage and current RMS value) are
calibrated and any DC offset is rejected, thanks to the almost ideal linearity of
STPM01. Meter calibration is achieved by calibrating the device at just one measuring
point (fast digital calibration), most often at nominal values, let's say, 230 VRMS, 5 ARMS,
50Hz.
This may simplify the generation of reference line signals of accurate output values. If
accuracy is not guaranteed, the reference values of line signals for a calibration system can
be obtained by precision RMS meters.
Calibrating only voltage and current in a single operating point led to a very short (4-5 sec. in
an automated environment) calibration time.
If an application uses both current channels, they must both be compensated with the same
procedure. This cannot be done at the same time, due to multiplexed implementation of two
channels. In this case calibration time is increased (see paragraph "Two current channels
calibration").



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com