23 / 35 page ![]() UM0855 Data acquisition quick start Doc ID 16617 Rev 1 23/35 5 Data acquisition quick start This section describes the basic steps that must be performed to acquire the yaw data from the STEVAL-MKI0xxV1: 1. Connect the STEVAL-MKI0xxV1 to the USB port. 2. Start the STEVAL-MKI0xxV1 GUI. 3. Select the virtual COM port and click on the “Connect” button ( Figure 9, ref 1). 4. Select the destination file to which the yaw data must be saved by clicking “Save” ( Figure 9, ref 2) in the main control section (optional). 5. Use the tab menu to display the desired function. 6. Click on the “START” (or “STOP”) button to activate (or stop) the sensor data collection, saving to file, and screen plotting functions. 7. To close the application, click on “Disconnect” and then click on “Exit”. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|