21 / 24 page ![]() DocID16612 Rev 6 21/24 AN3101 Low speed internal oscillator measurement 23 Figure 13. LSI frequency measurement flow 3.3 LSI measurement demo description The demo provided with this application note shows the importance of measuring the LSI frequency value before starting to use peripherals clocked by this type of clock. In this example the independent watchdog (IWDG) is used to generate a reset after 12 ms. Since the LSI clock is not accurate, the reset will occur slightly after or before the required time-out. Hence, measuring the LSI frequency enhances the time-out accuracy. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|