| Electronic Components Datasheet Search |
|
AN3413 Datasheet(PDF) 7 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3413 Datasheet(HTML) 7 Page - STMicroelectronics |
|
7 / 18 page ![]() DocID018933 Rev 2 7/18 AN3413 Application description 17 When the used push button is pressed again, the power consumption measurement functions are launched. These functions consist of configuring the device for each low power consumption mode and then measuring and displaying the result on the LCD panel. Figure 3. Function Change state diagram BAR0 to BAR3 are used by the application to indicate ongoing measurements as shown in Table 1. In order to save power during the IDD measurement in Stop mode without LCD, the LCD is switched off. Once the measurement is performed the LCD is switched on to display the power consumption value. Table 1. Bars and LCD display linked to functions Function Bars VDD / Linear sensor / Touch buttons Run mode / Sleep mode MS19812V1 reset START RUN SLEEP IDD VDD meas LPRUN LPSLEEP IDD TOUCH LINEAR SENSOR STOP IDD STANDBY IDD User button pressed TOUCHKEYS |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|