Electronic Components Datasheet Search
  British  ▼
ALLDATASHEET.CO.UK

X  

RT9481 Datasheet(PDF) 30 Page - Richtek Technology Corporation

Part # RT9481
Description  Easy to Use Power Bank Solution
PDF  41 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  RICHTEK [Richtek Technology Corporation]
Direct Link  http://www.richtek.com
Logo RICHTEK - Richtek Technology Corporation

RT9481 Datasheet(HTML) 30 Page - Richtek Technology Corporation

Back Button RT9481 Datasheet HTML 26Page - Richtek Technology Corporation RT9481 Datasheet HTML 27Page - Richtek Technology Corporation RT9481 Datasheet HTML 28Page - Richtek Technology Corporation RT9481 Datasheet HTML 29Page - Richtek Technology Corporation RT9481 Datasheet HTML 30Page - Richtek Technology Corporation RT9481 Datasheet HTML 31Page - Richtek Technology Corporation RT9481 Datasheet HTML 32Page - Richtek Technology Corporation RT9481 Datasheet HTML 33Page - Richtek Technology Corporation RT9481 Datasheet HTML 34Page - Richtek Technology Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 30 / 41 page
background image
RT9481
Copyright © 2015 Richtek Technology Corporation. All rights reserved.
is a registered trademark of Richtek Technology Corporation.
www.richtek.com
DS9481-00 June 2015
30
Function
Register
Address
b[7]
(MSB)
b[6]
b[5]
b[4]
b[3]
b[2]
b[1]
b[0]
(LSB)
Charger
Status1
0X08
Meaning
UUGPUMP_
STAT
VBAT_
LVL
CHG_
STAT
CHG_ Done
BOOST_
STAT
PWR_
Rdy
SWBASE_EN
SWITCHING
_EN
Default
0
1
0
0
0
0
1
0
Read/
Write
R
R
R
R
R
R
R/W
R/W
UUGPUMP_STAT
UUG pump enable status
0 : UUG pump is disable
1 : UUG pump is enable
VBAT_LVL
Battery voltage level detect under charging
0 : Battert voltage is lower than pre-charge level
1 : Battery voltage is higher than fast-charge level
CHG_STAT
Charging Status
0 : Charging is not in progress
1 : Charging is in progress
CHG_Done
Charger Done indication bit
0 : Charging is not done
1 : Charging is done
BOOST_STAT
0 : Not in Boost mode
1 : Boost mode
PWR_Rdy
Power status bit
0 : VBUS > VBUS_OVP or VBUS < VBUS_UVLO or VBUS < ISENSN + VSLP (Power Fault)
1 : VBUS_UVLO < VBUS < VBUS_OVP & VBUS > ISENSN + VSLP (Power Ready)
SWBASE_EN
Switching charger base circuit enable
0 : Disabled
1 : Enabled
SWITCHING_EN
Charger/ Boost enable
0 : Charger/ Boost is disabled
1 : Charger/ Boost is enabled



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com