| Electronic Components Datasheet Search |
|
MICRF002 Datasheet(PDF) 10 Page - Micrel Semiconductor |
|
|
|||||||||||||||||||||||||||||
MICRF002 Datasheet(HTML) 10 Page - Micrel Semiconductor |
|
10 / 13 page ![]() QwikRadio tm 10 July 1999 MICRF002 MICRF002 Micrel 1. Selecting REFOSC Frequency ft (FIXED Mode) As with any superheterodyne receiver, the difference between the (internal) Local Oscillator (LO) frequency flo and the incoming Transmit frequency ftx must ideally equal the IF Center frequency. Equation (1) may be used to compute the appropriate flo for a given ftx: flo = ftx ± 1.064 * (ftx / 390) (1) where ftx and flo are in MHz. Note that two values of flo exist for any given ftx, distinguished as “high-side mixing” and “low-side mixing”, and there is generally no preference of one over the other. After choosing one of the two acceptable values of flo, use equation (2) to compute the REFOSC frequency ft: ft = flo / 64.5. (2) Here ft is in MHz. Connect a crystal of frequency ft to the REFOSC pin of the MICRF002. 4 decimal-place accuracy on the frequency is generally adequate. The following table identifies ft for some common Transmit frequencies when the MICRF002 is operated in FIXED mode. Transmit Freq. ftx (MHz) REFOSC Freq. ft (MHz) 315 418 433.92 4.8970 6.4983 6.7458 2. Selecting REFOSC Frequency ft (SWP Mode) Selection of REFOSC frequency ft in SWP mode is much simpler than in FIXED mode, due to the LO sweeping process. Further, accuracy requirements of the frequency reference component are significantly relaxed. In SWP mode, ft is given by equation (3): ft = ftx / 64.25. (3) Connect a ceramic resonator of frequency ft to the REFOSC pin of the MICRF002. 2-decimal place accuracy is generally adequate. (A crystal may also be used if desired, but may be necessary to reduce the Rx frequency ambiguity if the Tx frequency ambiguity is excessive. See Application Note TBD for further details.) 3. Selecting Capacitor CTH First step in the process is selection of a Data Slicing Level timeconstant. This selection is strongly dependent on system issues, like system decode response time and data code structure (e.g., existence of data preamble, etc.). This issue is too broad to discuss here, and the interested reader should consult the Application Note 22. Source impedance of the CTH pin is given by equation (4), where ft is in MHz: Rsc = 118k Ω * (4.90 / ft). (4) Assuming that a Slicing Level Timeconstant TC has been established, capacitor CTH may be computed using equation (5): CTH = TC / Rsc. (5) 4. Selecting CAGC Capacitor in Continuous Mode Selection of CAGC is dictated by minimizing the ripple on the AGC control voltage, by using a sufficiently large capacitor. It is Micrel’s experience that CAGC should be in the vicinity of 0.47 µF to 4.7µF. Large capacitor values should be carefully considered, as this determines the time required for the AGC control voltage to settle from a completely discharged condition. AGC settling time from a completely discharged (0-volt) state is given approximately by equation (6): ∆T = (1.333 * CAGC) – 0.44 (6) where CAGC is in microfarads, and ∆T is in seconds. 5. Selecting CAGC Capacitor in Duty-Cycle Mode Generally, droop of the AGC control voltage during shutdown should be replenished as quickly as possible after the IC is “turned-on”. Recall from the section “AGC Function and the CAGC Capacitor” that for about 10msec after the IC is turned-on, the AGC push-pull currents are increased to 45X their normal values. So consideration should be given to selecting a value for CAGC and a shutdown time period such that the droop can be replenished within this 10msec period. Polarity of the droop is unknown, meaning the AGC voltage could droop up or down. Worst-case from a recovery standpoint is downward droop, since the AGC pullup current is 1/10 th magnitude of the pulldown current. The downward droop is replenished according to the well-known equation (7): I / CAGC = ∆V / ∆T (7) where I = AGC Pullup current for initial 10msec (67.5 µA), CAGC is the AGC capacitor value, ∆T = Droop recovery time (<10msec), and ∆V is the droop voltage. For example, if user desires ∆T = 10msec, and chooses a 4.7 µF CAGC, then the allowable droop is about 144mV. Using the same equation with 200nA worst case pin leakage and assuming 1uA of capacitor leakage in the same direction, the maximum allowable ∆T (Shutdown time) is about 0.56 seconds, for droop recovery in 10msec. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |