9 / 16 page ![]() tAbLe 9: eLeCtriCAL CHArACteristiCs -55°C to +125°C CAse, 28 vin, 100% LoAD, Free run, unLess otHerwise sPeCiFieD. TRIpLE OUTpUT MODEL – MWR28515T 5 (MAIN) ±15 (AUXILIARIES) UNITS pARAMETER CONDITIONS MIN TYp MAX MIN TYp MAX OUTpUT VOLTAGE MAIN AND pOS. AUX 4.90 5.00 5.10 14.70 15.00 15.30 V NEG. AUX. — — — 14.62 15.00 15.38 OUTpUT CURRENT MAIN AND EITHER OUTpUT — — 3.0 — ±0.667 0.93 1 A VIN = 14 TO 50 V MAX TOTAL AUX — — — — — 1.34 OUTpUT pOWER MAIN AND EITHER OUTpUT — — 15 — ±10 14 1 W VIN = 14 TO 50 V MAX TOTAL AUX — — — — — 20 OUTpUT RIppLE TC = 25°C — 20 45 — 35 80 mV p-p 10 kHz - 20 MHz TC = -55°C TO +125°C — 20 60 — 35 100 LINE REGULATION MAIN AND pOS. AUX — 5 25 — 5 50 mV VIN = 14 TO 50 V NEG. AUX. — — — — 28 120 LOAD REGULATION MAIN AND +AUX., NL - FL — 5 25 — 50 50 mV BALANCED AUX. -AUX., NL - FL — — — — 25 100 CROSS REGULATION 2 EFFECT ON — — — — 250 600 mV TC = 25°C NEGATIVE AUXILIARY INpUT VOLTAGE CONTINUOUS 14 28 50 — — — V TRANSIENT 1 sec 1 — — 80 — — — V INpUT CURRENT NO LOAD — 50 70 — — — mA INHIBITED — 2.5 4 — — — INpUT RIppLE CURRENT 3 10 kHz - 20 MHz — 40 100 — — — mA p-p EFFICIENCY TC = 25°C 82 85 — — — — % TC = -55°C TO +125°C 81 — — — — — LOAD FAULT 4, 5 pOWER DISSIpATION — 7 9.5 — 5 9.5 W RECOVERY 1 — 15 20 — — 20 ms STEp LOAD RESpONSE 5 , 6 TRANSIENT — ±75 ±350 — ±175 ±600 mV pk 50% - 100% - 50% RECOVERY — 230 400 — 145 600 µs STEp LINE RESpONSE 1, 5, 7 TRANSIENT — ±100 ±400 — ±200 ±400 mV pk 14 - 40 - 14 VIN RECOVERY — 400 900 — 200 700 µs START-Up 5, 8 DELAY — 15 20 — — 20 ms OVERSHOOT 1 — 5 50 — 5 70 mV pk CApACITIVE LOAD 1, 9 25°C — — 1000 — — 500 µF Notes 1. Guaranteed by design and/or analysis. Not an in-line test. 2. Effect on negative output when switching loads simultaneously from/to 30%-70% where 100% is the total power of both auxiliaries. 3. At loads <20% of full load, higher input ripple current is possible. 4. Limit applies to both main and auxiliary outputs, tested separately. 5. Recovery and startup times are measured from application of the transient or change in condition to the point at which VOUT is within 1% of final value. CL = 0. 6. Step load transition time 10 µs ±1 µs. 7. Step line transition time 100 µs ±20 µs. 8. Tested on release from inhibit. 9. No effect on dc performance. Applies to each auxiliary. Crane Aerospace & Electronics Power Solutions MWRTripleDC-DCConverters 14TO50VOlTInpUT-35WaTT www.craneae.com/interpoint MWR Rev AD - 2016.05.20 page 9 of 16 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |