| Electronic Components Datasheet Search |
|
CPC44055ST Datasheet(PDF) 4 Page - IXYS Corporation |
|
|
|||||||||||||||||||||||||||||
CPC44055ST Datasheet(HTML) 4 Page - IXYS Corporation |
|
4 / 8 page ![]() INTEGRATED CIRCUITS DIVISION R02 www.ixysic.com 4 CPC44055ST 3 UL Approved Ratings 3.1 General Loads 3.2 Tungsten Lamp Load 3.3 Motor Load 3.4 Electronic Ballast Load Note: *Heat Sink Used for UL Testing: Ohmite MA-302-55E Voltage (VAC) Current (A) Surrounding Air Temperature (°C) 20 - 280 4.75 40 20 - 280 2.5 85 51 - 150 15 (with Heat Sink*) 40 51 - 150 11.75 (with Heat Sink*) 70 Voltage (VAC) Current (A) Surrounding Air Temperature (°C) 20 - 280 4.75 40 20 - 280 2.5 85 51 - 150 15 (with Heat Sink*) 40 51 - 150 11.75 (with Heat Sink*) 70 Voltage (VAC) Current Surrounding Air Temperature (°C) 220 - 240 1/3 HP, 3.6 FLA 40 220 - 240 1/6 HP, 2.2 FLA 85 110 - 120 1/2 HP, 9.8 FLA (with Heat Sink*) 40 110 - 120 1/2 HP, 9.8 FLA (with Heat Sink*) 70 Voltage (VAC) Current (A) Surrounding Air Temperature (°C) 120 535 120 15 (with Heat Sink*) 40 120 10 (with Heat Sink*) 70 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|